Time
3.2.2
PTP Version 1 (MS20/MS30, PowerMICE,
MACH 104, MACH 1040)
You select the PTP version you will use in the Time:PTP:Global dialog.
PTP Version 1, Global Settings
Parameter
Meaning
Sync Interval
Period for sending synchronization
messages.
Entered in seconds.
Subdomain
Name of the PTP subdomain to
name
which the local clock belongs.
Preferred
Defines the local clock as the
Master
preferred master. If PTP does not
find another preferred master, then
the local clock is used as the
grandmaster clock. If PTP finds
other preferred masters, then PTP
determines which of the preferred
masters is used as the grandmaster
clock.
Table 18: Function IEEE 1588/PTPv1
Parameter
Meaning
Offset to Master
Deviation of the local clock from the
[ns]
reference clock in nanoseconds.
Runtime to
Single signal runtime between the
Master [ns]
local device and reference clock in
nanoseconds.
Grandmaster
MAC address of the grandmaster
UUID
clock (Unique Universal Identifier).
Parent UUID
MAC address of the master clock
with which the local time is directly
synchronized.
Clock Stratum
Qualification of the local clock.
Clock identifier
Clock properties (e.g accuracy,
epoch, etc.).
Table 19: Status IEEE 1588/PTPv1
78
3.2 PTP (IEEE 1588)
Possible Values
- sec-1
- sec-2
- sec-8
- sec-16
- sec-64
1 to 16 ASCII
characters, hex value
0x21 (!) through 0x7e
(~)
true
false
Possible Values
Default Setting
sec-2
_DFLT
false
Default Setting