interference. Complete full sensor
testing to verify proper communications,
even if within the specified range.
The device is designed for indoor use
only and should not be installed
outdoors. For proper sensor operation,
the room should be kept between 60°
and 120° F.
For optimal detection capabilities,
mount the sensor where someone will
most likely walk across the sensor
coverage area as opposed to directly
towards the sensor.
The horizontal position of the sensor can
be altered while mounting by lifting the
sensor about 1/3 of the way off the
mounting piece and rotating it. Position
the sensor such that activity of interest
will be detected within the sensor field
of view. Be sure to properly secure the
sensor with the provided pin and screw.
Leave at least 3 inches of clearance
above the sensor to allow for battery
replacement without uninstalling the
bracket mount.
Mounting Hardware
The ADC-IS-100-LP and ADC-IS-100-SL mounting
hardware packet contains:
Mounting Arm- The mounting arm
attaches to the back of the sensor and to
the wall mounting bracket. To attach
the mounting arm to the sensor, slide
the back cover off the sensor. Insert the
mounting arm pins into the holes on the
back of the sensor. Secure the back of
the sensor to the mounting arm with the
provided screw and washer.
Mounting Bracket- The sensor comes
with 2 mounting brackets for different
mounting scenarios. Use the provided
Installation Instructions
1" screws and anchors to attach the
bracket to the wall.
Flat Wall Bracket- Use for
•
mounting on flat surfaces (non-
corner).
Corner Wall Bracket- Use for
•
mounting in corner (non-flat)
scenarios.
Lock Pin- The lock pin is used to secure
the horizontal position of the sensor
once placed on the mounting bracket.
Once the sensor is placed on the
mounting bracket, slide the lock pin into
the hole and push to secure.
Assembly Pack- The assembly pack
includes the necessary mounting
accessories for installation the sensor.
1'' Screws (2)- For securing the
•
mounting bracket to wall
Anchors (2)- For securing the
•
mounting bracket to wall
Washer (1)- For securing sensor
•
back to mounting arm
¼" Screws (2)- For securing
•
sensor back to mounting arm;
For securing the lock pin
Installation Steps
1) Determine sensor mounting location
based on installation scenario and
according to Installation Guidelines
indicated above.
2) Choose applicable mounting bracket for
customer scenario. Mark location of
bracket holes on mounting surface at a
height of 8 feet.
3) Secure the mounting bracket to the
mounting surface using the anchors and
wall bracket screws.
4) Attach the mounting arm to the back of
the sensor. Slide the sensor back off and
ADC-IS-100-LP
2
Need help?
Do you have a question about the ADC-IS-100-LP and is the answer not in the manual?