8. Approvals
The standard version DPK pumps have been tested
by TÜV according to EC Council Machinery Directive
98/37/EC, registration no. AM 5014341 3 0001 and
report no. 13009106 001.
9. Type key
The pump can be identified by the type designation stated on the pump nameplate. See section 7. Nameplate.
Code Example
DPK
Drainage pump
Free passage:
10
Maximum solids size [mm]
Pump discharge:
80
Nominal diameter of pump discharge port [mm]
Code for output power, P2:
22
P2* = Code number from type designation / 10 [kW]
Equipment:
-
Standard
S
Sensor(s)
Frequency:
5
50 Hz
6
60 Hz
Voltage and starting method:
0D
380-415 V, DOL
1D
380-415 V, Y/D
0E
220-240 V, DOL
1E
220-240 V, Y/D
*
Exception: Code 075 = 0.75 kW.
6
DPK
.10
.80
22
.S .5
0D