Original installation and operating instructions.
CONTENTS
1.
2.
2.1
3.
3.1
3.2
3.3
3.4
3.5
3.6
4.
4.1
4.2
5.
5.1
5.2
6.
7.
8.
8.1
8.2
9.
9.1
9.2
9.3
9.4
10.
11.
12.
13.
8
14.
Page
8
8
10
15.
10
10
Warning
10
Prior to installation, read these
10
installation and operating instructions.
10
Installation and operation must comply
10
with local regulations and accepted
10
codes of good practice.
11
11

1. Symbols used in this document

11
12
Warning
12
If these safety instructions are not
13
observed, it may result in personal
14
injury!
14
14
Warning
15
If these instructions are not observed,
16
it may lead to electric shock with
16
consequent risk of serious personal
17
injury or death.
17
Warning
These instructions must be observed
17
for explosion-proof pumps. It is
17
advisable also to follow these
18
instructions for standard pumps.
18
18
If these safety instructions are not
18
observed, it may result in malfunction
19
or damage to the equipment!
19
19
Notes or instructions that make the job
20
Note
easier and ensure safe operation.
20
20

2. General description

20
The electronic Grundfos DP and EF pumps
21
incorporate a controller and motor-protective
functions. They only need to be connected to the
21
mains supply.
21
The controller offers the following benefits:
22
Built-in level and dry-running sensors.
22
Built-in motor protection.
22
22
Pump alternation.
23
If several pumps are installed in the same tank,
24
the control logic incorporated in the pump will
25
ensure that the load is distributed evenly among
25
the pumps over time.
26
26
27
27
27
27
27
27
27
27

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DP 10.50 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Grundfos DP 10.50

  • Page 1: Table Of Contents

    11.4 Resetting the pump 2. General description Maintenance and service 12.1 Recommended cleaning intervals The electronic Grundfos DP and EF pumps for sensors in standard pumps incorporate a controller and motor-protective 12.2 Required cleaning intervals for functions. They only need to be connected to the sensors in explosion-proof pumps mains supply.
  • Page 2 Fig. 2 DP 10.65 pump pumping domestic and industrial wastewater. Two types of pumps are available: • DP 10.50 and DP 10.65 drainage pumps • EF 30.50 effluent pumps. The pumps are designed for free-standing installation. DP 10.65.26 pumps can be installed on an auto- coupling system.
  • Page 3: Applications

    40 °C. Warning The pumps must under no 3.6 Density of pumped liquid circumstances pump combustible liquids. Maximum 1000 kg/m In the case of higher values, see WebCAPS on www.grundfos.com, or contact Grundfos.
  • Page 4: Approvals

    4. Approvals The standard versions of the DP and EF pumps have been tested by VDE. The explosion-proof versions have been approved by KEMA according to the ATEX directive. 4.1 Approval standards All versions have been approved by LGA (notified body under the Construction Products directive) according to EN 12050-1 and EN 12050-2.
  • Page 5: Identification

    5. Identification 5.1 Nameplate The nameplate states the operating data and approvals applying to the pump. The nameplate is fixed to the side of the stator housing opposite the unit. The additional nameplate supplied with the pump can be fixed close to the tank. AUTO ADAPT Type:...
  • Page 6: Type Key

    5.2 Type key Example DP10.50.15.E.Ex.2.1.502 10 .50 .15 .E .Ex .2 .1 .5 02 Type range Grundfos sewage pumps Material Standard, cast iron Maximum spherical impeller clearance [mm] Pump discharge Nominal diameter of pump discharge port [mm] Output power, P2...
  • Page 7: Safety

    See fig. 1, 2 or 3 (pos. 7). If the protective cap is sensory or mental capabilities must not defective, contact your nearest Grundfos company. use this product, unless they are under All lifting equipment must be rated for the purpose...
  • Page 8: Installation On Auto Coupling

    3. Assemble the discharge line in accordance with pump when in operation. the generally accepted procedures and without exposing the line to distortion or tension. We recommend always to use Grundfos 4. Insert the guide rails in the auto-coupling base accessories to avoid malfunction due Note unit, and adjust the length of the rails accurately to incorrect installation.
  • Page 9: Free-Standing Submerged Installation

    Hookup auto-coupling system, see fig. C, If several pumps are installed in the page 534. same tank, the pumps must be installed Note Proceed as follows: at the same level in order to allow 1. Fit the crossbar in the tank. optimum pump alternation.
  • Page 10: Ciu Unit (Communication Interface)

    2 A 230 VAC All pumps are supplied with 10 metres of cable and a free cable end. A possible replacement of the cable must be carried out by Grundfos or Caution an authorised service workshop. 9.1 CIU unit (communication interface)
  • Page 11: Configuration

    10. Configuration 10.3 Start level set The pump start level may be affected by the 10.1 Default settings barometric pressure. In the case of long intervals between start and stop, the start level may differ The pump is supplied from the factory with the from the set level.
  • Page 12: Thermal Switches

    7. Check that the system has been filled with liquid If the pump has to be restarted and vented. The pump is self-venting. manually repeatedly, contact Grundfos 8. Switch on the power supply to the pump. or an authorised service workshop.
  • Page 13: Operating Modes

    Warning Except for service on the hydraulic part, all other service work must be carried out by Grundfos or an authorised service workshop approved for servicing Ex products. Before carrying out maintenance and service, it must be ensured that the pump has been thoroughly Fig.
  • Page 14: Recommended Cleaning Intervals For Sensors In Standard Pumps

    Except for service on the hydraulic built up in the chamber. Do not remove part, all other service work must be the screws until the pressure has been carried out by Grundfos or an fully relieved. authorised service workshop approved for servicing Ex products.
  • Page 15: Adjustment Of Impeller Clearance

    12.4 Adjustment of impeller clearance 12.6 Cleaning the sensors For position numbers, see page 552, 553 or 554. Proceed as follows: 1. DP pumps only: Slacken and remove the screws (pos. 188c) holding the suction strainer (pos. 84). Remove the strainer. 2.
  • Page 16: Oil Change

    For oil quantity, see section 12.3 Inspection be intact. If it is worn and must be replaced, intervals. the pump must be checked by Grundfos or 3. Fit both oil screws using the packing material an authorised service workshop. included in the kit.
  • Page 17: Service Kits

    96115109 EF 30.50.11 96115102 Impeller complete with adjusting Impeller EF 30.50.15 96115103 screw, shaft screw and key DP 10.50.09 96115104 DP 10.50.15 96115105 DP 10.65.26 96115106 1 litre of oil, type Shell Ondina 917. See section 12. Maintenance and All types...
  • Page 18: Built-In Protection

    All single-phase 96984142 capacitor bracket and O-rings for cover pumps A possible replacement of the cable must be carried out by Grundfos or an authorised service Caution workshop. 12.10 Built-in protection 12.11 Contaminated pumps The motor incorporates an unit which protects the Warning motor in various situations.
  • Page 19: Fault Finding Chart

    Fault in motor electronics. Have the motor checked and repaired by a Grundfos service engineer. f) Deposits on level or dry-running Clean the sensor(s). sensors. 2. The pump operates, but a) Impeller blocked by impurities.
  • Page 20: Technical Data

    This product or parts of it must be disposed of in an environmentally sound way: 1. Use the public or private waste collection service. 2. If this is not possible, contact the nearest Grundfos company or service workshop. Subject to alterations.

This manual is also suitable for:

Dp 10.65Ef 30.50