Page 1
GRUNDFOS INSTRUCTIONS DWK, DPK Safety instructions and other important information Installation and operating instructions Installation and operating instructions http://net.grundfos.com/qr/i/97515233 http://net.grundfos.com/qr/i/97515234...
Page 2
- Lift the pump in a way that the pump will Maximum 1000 kg/m not start swing. In the case of higher densities, contact Grundfos. - Place the pump on a solid foundation which is suitable to hold the weight.
CAUTION The following thermal protections can be found in Crushing hazard DWK pumps, depending on the specific pump type: Minor or moderate personal injury • thermal switch (Bi-metallic) type PTO or Klixon - Always check the lifting bracket and •...
Page 4
Operating levels of DWK The pump is not to be used for drinking water. Approvals The standard version of the DWK pumps has been tested by TÜV according to EC Council Machinery Directive 2006/42/EC, registration no. AM 50143413 and report no. 13009106 001.
1. Use the public or private waste collection service. Motor output power P2 [kW] 2. If this is not possible, contact the nearest Grundfos company or service workshop. Power factor The crossed-out wheelie bin symbol on Maximum liquid temperature [°C]...
Page 7
Appendix Wiring diagrams Fig. 1 Direct-on-line starting L1 L2 L3 S / S MCCB F / L F / L MCCB O P . T R T / P T / P S / S S / S GU 01 / GU 02 U1 V1 W1 W2 U2 V2 T / P T / P S / S S / S...
My firma Grundfos prohlašujeme na svou plnou odpovědnost, že DPK, DWK, to which the declaration below relates, is in conformity výrobek DPK, DWK, na který se toto prohlášení vztahuje, je v souladu with the Council Directives listed below on the approximation of the s níže uvedenými ustanoveními směrnice Rady pro sblížení...
Page 10
– RoHS Directives (2011/65/EU and 2015/863/EU) Standard used: EN 50581:2012 This EC/EU declaration of conformity is only valid when published as part of the Grundfos safety instructions (99347040). Szekesfehervar, 2 October 2019 Róbert Kis Senior Manager D&E Waste Water Grundfos Holding A/S...
Page 14
Argentina China Hong Kong Bombas GRUNDFOS de Argentina S.A. GRUNDFOS Pumps (Shanghai) Co. Ltd. GRUNDFOS Pumps (Hong Kong) Ltd. Ruta Panamericana km. 37.500 Centro 10F The Hub, No. 33 Suhong Road Unit 1, Ground floor Industrial Garin Minhang District Siu Wai Industrial Centre 1619 Garín Pcia.
Page 15
Malaysia Serbia Turkey GRUNDFOS Pumps Sdn. Bhd. Grundfos Srbija d.o.o. GRUNDFOS POMPA San. ve Tic. Ltd. 7 Jalan Peguam U1/25 Omladinskih brigada 90b Sti. Glenmarie Industrial Park 11070 Novi Beograd Gebze Organize Sanayi Bölgesi 40150 Shah Alam Phone: +381 11 2258 740...
Need help?
Do you have a question about the DWK and is the answer not in the manual?