RANGE HOOD - Installation and use instructions
ENGLISH........................................2
FRANÇAIS...................................30
www.zephyronline.com

Advertisement

loading

Summary of Contents for Zephyr ALA-M90BBX

  • Page 1 Layers Wall ALA-M90BBX ALA-M90BWX ALA-E42BBX ALA-E42BWX Duo Wall ADU-M90BSX RANGE HOOD - Installation and use instructions ENGLISH........2 FRANÇAIS........30...
  • Page 2 INSTALLING THE DUCTWORK: ROOF CAP INTERNAL BLOWER NOTE: To reduce the risk of fire, use only metal ductwork. 6” ROUND DUCT 1. Decide where the ductwork will run between the hood and the outside. DUCT COVER 2. A straight, short duct run using a minimum WALL 6”...
  • Page 3 hardware bag (Fig.10). 5. Remove the blower plate unscrewing the (4) 3.9x9.5 mm screws (Fig.11). FIG. 11 (4) MOUNTING SCREWS 6. Install internal blower into blower plate and (Supplied with the motor) secure using (4) screws (supplied with the internal blower) - See Fig.12. FIG.
  • Page 4: Internal Blower Wiring

    INTERNAL BLOWER WIRING Note: This range hood must be properly grounded. The unit should be installed by a qualified electrician in accordance with all applicable national and local electrical codes. 1. Make connections (A, B,C) (Fig.14). 2. Secure capacitor box screwing the (2) 3.9x9.5 mm screws (Fig.14D). 3.
  • Page 5 8. Install the front plate and electrical system (4) MOUNTING SCREWS box using (4) 3.9x6 mm screws (Fig.15). (3.9 x 6 mm Flat Head) FIG. 15 9. Place the 6” metallic flange provided on the blower’s air outlet (Fig.16). FIG. 16 - 18 -...
  • Page 6 REMOTE BLOWERS (EXTERNAL AND IN-LINE) CAUTION: To reduce risk of fire and electric shock, install this range hood only with External Blower Model CBE-1000, and In-Line Blower Model PBN-1000A. Other blowers cannot be substituited. INSTALLING THE DUCTWORK: REMOTE BLOWER NOTE: To reduce the risk of fire, use only metal ductwork. 1.
  • Page 7 INSTALLING THE REMOTE ELECTRICAL SYSTEM BOX BLOWER NOTE: The following instructions are for preparing the hood for use with external or in-line blower models CBE-1000 or PBN- 1000A. For blower installation details refer to manual included with the blower. 1. Remove the electrical system box from chimney frame by removing duct tape.
  • Page 8: Remote Blower Wiring

    REMOTE BLOWER WIRING 1. Remove the cover from the wiring box marked “120 Vac input”. 2. Remove one knockout from the (2) wiring boxes (box marked “120 Vac input” and box marked “motor connection”). 3. Run 4-wire plus ground power cable from the remote blower to the remote blower wiring box marked “motor connection”...
  • Page 9: Install The Hood

    INSTALL THE HOOD Model Duo Remove the plastic protective film from all exterior surfaces, duct covers and filters, prior to final installation FRAMING BEHIND WOOD CROSS SUPPORT 1. Construct wood wall framing that is flush with interior surface of wall studs (Fig.22/23). Make sure: a) the framing is centered over installation location.
  • Page 10 INSTALL DUCT COVER (2) MOUNTING SCREWS MOUNTING BRACKET (3.9 x 6 mm Flat Head) DUCTED AND NON-DUCTED 1.Assemble the duct cover mounting bracket, adjusting outside width as shown. (Fig.24) 2.Carefully center the mounting bracket directly over the range hood location. 3.Secure the bracket assembly to the ceiling using (2) 4.8 x 38mm mounting screws and FIG.24...
  • Page 11 DUCTED INSTALLATION ONLY Note: Rooms with 10 to 12 foot ceiling 6-INCH DIA. require duct cover extension model METAL DUCT Z1C-00LA, available from your local dealer. Discard the upper duct cover supplied with the range hood and replace it with the longer flue extension.
  • Page 12 NON-DUCTED INSTALLATION ONLY Note: a. Purchase Model ZRC-01LA Non-ducted Recirculating Kit from your local dealer, sold separately. b. Rooms with 10 to 12 foot ceilings require duct cover extension model Z1C-00LA, available from your local dealer. Discard (4) MOUNTING SCREWS (3.9 x 6mm the upper duct cover supplied with the Flat Head) range hood and replace it with the longer...
  • Page 13 4. Temporarily secure the upper and lower duct covers together with duct tape as shown (Fig.31). FIG.31 5. Lift the duct covers into position above the hood. Secure upper duct cover to the duct covers mounting bracket with (2) 3.9 (2) MOUNTING SCREWS x 9,5 mm screws (Fig.32).
  • Page 14: Mesh Filters

    MESH FILTERS NOTE: prior to use, remove protective film from the filter frame. DUCTED AND NON-DUCTED HOODS 1. To remove the MESH filter, pull down on latch tab to disengage the filter from the hood. Tilt the filter downward and remove (Fig.34).