Advertisement

Quick Links

Layers Wall
ALA - M90ABX
ALA - M90AWX
ALA - E42ABX
ALA - E42AWX
Edge Wall
AED - M90ASX
www.zephyronline.com
Surface Wall
ASU - M90ASX
ASU - E42ASX
Duo Wall
ADU - M90ASX

Advertisement

Table of Contents
loading

Summary of Contents for Zephyr ARC ALA-M90ABX

  • Page 1 www.zephyronline.com Layers Wall Surface Wall ALA - M90ABX ASU - M90ASX ALA - M90AWX ASU - E42ASX ALA - E42ABX ALA - E42AWX Edge Wall Duo Wall AED - M90ASX ADU - M90ASX...
  • Page 2 www.zephyronline.com HOTTE PER CUISINE - Notice d’utilisation...Pag. 27 CAMPANA EXTRACTORA - Manual de utilización...Pag. 53 CAPPA ASPIRANTE - istruzioni per l’uso...Pag. 79 - 2 -...
  • Page 3: Table Of Contents

    SAFETY INSTRUCTIONS....................pag. 4 LIST OF MATERIALS......................pag. 7 DUCTING CALCULATION SHEETS................pag. 11 HOOD SPECIFICATION....................pag. 12 INSTALLATION - INTERNAL BLOWER..................pag. 16 - EXTERNAL & IN-LINE BLOWER PREPARATION.......pag. 18 - DUCTING OPTIONS..................pag. 20 - MOUNTING THE RANGE HOOD.............pag. 21 - POWER SUPPLY CONNECTION..............pag. 22 - MOUNTING THE DUCT COVER...............pag.
  • Page 4: Safety Instructions

    www.zephyronline.com IMPORTANT SAFETY INSTRUCTIONS FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORTANT: Save these Instructions for the Local Electrical Inspectors use. INSTALLER: Please leave these Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference.
  • Page 5 settings. B. Always turn hood ON when cooking at high heat or when fl ambeing foods ( i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambè ). C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or fi lter. D.
  • Page 6 www.zephyronline.com through the fl ue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
  • Page 7: List Of Materials

    Models: ALA-M90ABX / ALA-M90AWX / ALA-E42ABX / ALA-E42AWX Duct Cover Bracket Duct Covers Blower Housing Electrical Junction Box Glass Range Hood Body Light Bulbs Decorative Mesh Filters TYPE DESCRIPTION N° 1 + 1 1/8" x 1/4" 1/8" x 2/4" 1/4" x 2-3/4" - 7 -...
  • Page 8 www.zephyronline.com Models: ASU-M90ASX / ASU-E42ASX Duct Cover Bracket Duct Covers Electrical Junction Box Blower Housing Control Glass Range Hood Light Bulbs Body Decorative Mesh Filters TYPE DESCRIPTION N° 1 + 1 1/8" x 1/4" 1/8" x 2/4" 1/4" x 2-3/4" - 8 -...
  • Page 9 Models: AED M90ASX Duct Covers Duct Cover Bracket Control Range Hood Body Light Panel Light Bulbs Decorative Mesh Filters TYPE DESCRIPTION N° 1 + 1 1/8" x 1/4" 1/8" x 2/4" 1/4" x 2-3/4" - 9 -...
  • Page 10 www.zephyronline.com Model: ADU-M90ASX Duct Cover Bracket Duct Covers Electrical Junction Box Control Blower Housing Range Hood Body Light Panel Light Bulbs Decorative Mesh Filters TYPE DESCRIPTION N° 1 + 1 1/8" x 1/4" 1/8" x 2/4" 1/4" x 2-3/4" - 10 -...
  • Page 11: Ducting Calculation Sheets

    Maximum Duct Length: For satisfactory air movement, the total duct length should not exceed 100 equivalent feet. - 11 -...
  • Page 12: Hood Specification

    www.zephyronline.com Models: ALA-M90ABX / ALA-M90AWX / ALA-E42ABX / ALA-E42AWX side of hood front of hood top of hood - 12 -...
  • Page 13 Models: ASU-M90ASX / ASU-E42ASX side of hood front of hood top of hood - 13 -...
  • Page 14 www.zephyronline.com Models: AED-M90ASX side of hood front of hood top of hood 12-1/16" 11-1/4" 35-3/8" Wood Trim Dimensions 5/8" Thickness - 14 -...
  • Page 15 Models: ADU-M90ASX side of hood front of hood top of hood 12-1/16" 11-1/4" 35-3/8" Wood Trim Dimensions 1-5/8" Thickness - 15 -...
  • Page 16: Internal Blower

    www.zephyronline.com The following instructions are for installing the internal blower. CAUTION: To reduce the risk of fi re and electric shock, install this range- hood only with internal blower models MT-020 provided with the kit cod CBI-600A. For external and in-line blower prepa- ration please turn to page 18.
  • Page 17 6. Attach the 6 pin male molex connector from blower wire to the 6 pin female molex connector located inside the blower housing. See Fig.6 7. Install blower and blower plate into blower housing by following the reverse instructions from step 2 then use the screws provided to complete installa- tion.
  • Page 18: External & In-Line Blower Preparation

    www.zephyronline.com The following instructions are for preparing the hood for use with an ex- ternal or in-line blowers models CBE-1000 or PBN-1000A. CAUTION: To reduce the risk of fi re and electric shock, install this rangehood only with remote blowers rated maximum 6.2 A. For internal blower instructions please turn to page 16.
  • Page 19 6. Insert the 6 pin female molex connector into the junction box. See Fig. 6A. Secure remote blower junction box to top of blower housing using (2) screws. See Fig. 6B 7. Feed remote blower wire harness through remote blower junction box cover and Connect the wires with those inside the junction box.
  • Page 20: Ducting Options

    www.zephyronline.com WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating op- tion. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certif ed Silver Tape or Duct Tape.
  • Page 21: Mounting The Range Hood

    MOUNTING HEIGHTS The range hood must be installed at a minimum height of 24 inches (61cm) from the cooking surface. If a connecting duct work composed of two parts is used, the upper part must be placed outside the lower part. Do not connect the range hood duct to the same duct used to exhaust hot air or fumes from another appliance.
  • Page 22: Power Supply Connection

    www.zephyronline.com GENERAL • Carefully read the following important information regarding installation safety and maintenance. Keep this information booklet accessible for further consultations. POWER SUPPLY CONNECTION For connection to the power supply refer to the following: 1. Lift the bottom part of the duct cover and secure it carefully using adhesive tape.
  • Page 23: Mounting The Duct Cover

    MOUNTING THE DUCT COVER Models: ALA-M90ABX / ALA-M90AWX / ALA-E42ABX / ALA-E42AWX / AED- M90ASX / ADU-M90ASX 1. Install the electrical wiring and test hood for functions prior to installing the duct covers. 2. If using hood in air recirculating mode make sure to install the air diverter plate prior to mounting the duct covers.
  • Page 24 www.zephyronline.com Models: ASU-M90ASX and ASU-E42ASX 1. Install the electrical wiring and test hood for functions prior to installing the duct covers. 2. If using hood in air recirculating mode make sure to install the air diverter plate prior to mounting the duct covers. See the manual included with the recirculating kit for more instructions.
  • Page 25: Maintenance

    MAINTENANCE • It is recommended to operate the appliance prior to cooking. It is recommended to leave the appliance in operation for 5 minutes after cooking is completed in order to completely eliminate cooking vapors and odors. The proper function of the range hood is conditioned by the regularity of maintenance.
  • Page 26: List Of Parts And Accessories

    www.zephyronline.com DESCRIPTION HOOD PART# REPLACEMENT PARTS Light Bulb GU4, 20W (each) ALA, ASU Z0B0030 Light Bulb G4, 20W (each) ADU, AED Z0B0013 OPTIONAL ACCESSORIES Recirculating Kit ALA, ADU, AED ZRC-00LA Recirculating Kit ZRC-00SU Replacement Charcoal Filters ALA, ADU, AED, ASU Z0F-00AC Duct Cover Extension ALA, ADU, AED...
  • Page 27 3LIK0482...

Table of Contents