  • Page 1 Duo Is. ADL-M90ASX ADL-E42ASX Layers Is. ALL-M90ABX ALL-M90AWX ALL-E42AWX ALL-E42ABX www.zephyronline.com...
  • Page 2 www.zephyronline.com HOTTE PER CUISINE - Notice d’utilisation...Pag. 25 CAMPANA EXTRACTORA - Manual de utilización...Pag. 48 CAPPA ASPIRANTE - istruzioni per l’uso...Pag. 73 - 2 -...
  • Page 3: Table Of Contents

    SAFETY INSTRUCTIONS...pag. 4 LIST OF MATERIALS...pag. 7 DUCTING CALCULATION SHEETS...pag. 9 HOOD SPECIFICATION...pag. 10 INSTALLATION - INTERNAL BLOWER...pag. 12 - EXTERNAL & IN-LINE BLOWER PREPARATION...pag. 14 - DUCTING OPTIONS...pag. 16 - MOUNTING THE RANGE HOOD...pag. 17 - POWER SUPPLY CONNECTION...pag. 20 MAINTENANCE...pag.
  • Page 4: Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORTANT: Save these Instructions for the Local Electrical Inspectors use. INSTALLER: Please leave these Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference. Take care when using cleaning agents or detergents.
  • Page 5 settings. B. Always turn hood ON when cooking at high heat or when fl ambeing foods ( i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambè ). C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or fi lter. D.
  • Page 6 www.zephyronline.com through the fl ue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
  • Page 7: List Of Materials

    Models: ADL-M90ASX / ADL-E42ASX Duct Covers Control Light Panel Blower Housing TYPE DESCRIPTION 1/4" x 2-3/4" - 7 - Support Frame Assembly Range Hood Body Light Bulbs Decorative Mesh Filters N° 1 + 1 1/8" x 1/4"...
  • Page 8 Models: ALL-M90ABX / ALL-M90AWX / ALL-E42AWX / ALL-E42ABX Duct Covers Glass Control Light Bulbs www.zephyronline.com TYPE DESCRIPTION 1/4" x 2-3/4" - 8 - Support Frame Assembly Blower Housing Range Hood Body Decorative Mesh Filters N° 1 + 1 1/8" x 1/4"...
  • Page 9: Ducting Calculation Sheets

    Maximum Duct Length: For satisfactory air movement, the total duct length should not exceed 100 equivalent feet. - 9 -...
  • Page 10: Hood Specification

    www.zephyronline.com Models: ADL-M90ASX / ADL-E42ASX side of hood front of hood top of hood 13" 35-3/8" or 42" Wood Trim Dimensions 1-5/8" Thickness - 10 -...
  • Page 11 Models: ALL-M90ABX / ALL-M90AWX / ALL-E42AWX / ALL-E42ABX front of hood side of hood top of hood - 11 -...
  • Page 12: Internal Blower

    The following instructions are for installing the internal blower. CAUTION: To reduce the risk of fi re and electric shock, install this range- hood only with internal blower models MT-020 provided with the kit cod CBI-600A. For external and in-line blower preparation please turn to page 14.
  • Page 13 6. Attach the 6 pin male molex connector from blower wire to the 6 pin female molex con- nector located inside the blower housing. See Fig.6 7. Install the motor and bracket, inside the motor housing, completing the installation using the other screws (6 type B )that have been sup- plied.
  • Page 14: External & In-Line Blower Preparation

    The following instructions are for preparing the hood for use with an ex- ternal or in-line blowers models CBE-1000 or PBN-1000A. CAUTION: To reduce the risk of fi re and electric shock, install this rangehood only with remote blowers rated maximum 6.2 A. For internal blower instructions please turn to page 12.
  • Page 15 Note1: A cable lock (not included) may be re- quired by local codes. Please review local co- des for more information. 6. Reinstall the cover on the motor housing by following the instructions from step 2 in re- verse order. 7.
  • Page 16: Ducting Options

    www.zephyronline.com WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating op- tion. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/certifi ed Silver Tape or Duct Tape.
  • Page 17: Mounting The Range Hood

    MOUNTING HEIGHTS The range hood must be installed at a minimum height of 24 inches (61 cm) from the cooking surface. If a connecting duct work composed of two parts is used, the upper part must be placed outside the lower part. Do not connect the range hood duct to the same duct used to exhaust hot air or fumes from another appliance.
  • Page 18 into the attic to connect after the hood is installed. Fig.11 4. Place duct covers over assembled support frame until they rest on www.zephyronline.com 3. Place assembled support frames on top of hood and secure it to the hood body using 8 type B screws. Fig.12 the hood body.
  • Page 19 5. Position hole template on the ceiling paying at- tention that the arrow is positioned on the same side as the range hood controls. - Make 4, holes in the ceiling and drive in (3 type C) screws without completely tightening them.
  • Page 20: Power Supply Connection

    GENERAL • Carefully read the following important information regarding installation safety and maintenance. Keep this information booklet accessible for further consultations. POWER SUPPLY CONNECTION For connection to the power supply refer to the following: 1. Temporarily join the two duct covers by lifting the bottom one and then carefully securing it to the top by using adhesive tape.
  • Page 21 - Connect the electrical conduit to the Field Wiring Compartment using listed onduit fi ttings. - Carry out the power supplly connection in accordance with the national electric code, ANSI/NFPA 70-1999. 5. Replace the lid by following the instructions from step 3 in reverse order, ensu- ring that the tab on the lid is within the enclosure.
  • Page 22: Maintenance

    www.zephyronline.com MAINTENANCE • It is recommended to operate the appliance prior to cooking. It is recommended to leave the appliance in operation for 5 minutes after cooking is completed in order to completely eliminate cooking vapors and odors. The proper function of the range hood is conditioned by the regularity of maintenance.
  • Page 23: List Of Parts And Accessories

    DESCRIPTION REPLACEMENT PARTS Light Bulb G4, 20W (each) Light Bulb GU4, 20W (each) OPTIONAL ACCESSORIES Recirculating Kit Replacement Charcoal Filters Duct Cover Extension, Short (9” ceiling) Duct Cover Extension, Long (10”-12" ceiling) ADL, ALL Wood Trim, 90cm, Wenge Wood Trim, 90cm, Charcoal Wood Trim, 42in, Wenge Wood Trim, 42in, Charcoal To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368...