System Configuration and Programming
Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.
Master Station Guidance LEDs On/Off – Guidance LEDs uses function key LEDs to
show which functions are currently available. To turn this feature on or off:
1. Press the zone (blue) button.
2. Press the 2 button to toggle Guidance LEDs on/off.
3. Press the reset (black) button when finished.
1. Press the zone (blue) button.
System Radio Paging Mode:
2. Press the desired mode's button—its LED will light:
3 – No central radio paging
4 – Central paging enabled, call resets not sent to pagers.
5 – Central paging enabled, call resets sent to pagers.
3. Press the reset (black) button when finished.
1. Press the talk (gray) button for 7–10 seconds, until the LED on the reset
Set System Time & Date:
(black) button is lit.
2. Press the privacy (red) button.
3. Enter the time using the first row of selector keys (add a leading "0" if necessary):
Press two digits for the hour, press two digits for the minutes, and then press 0
for a.m., or 1 for p.m.
4. The privacy (red) button's LED will be flashing, to indicate that the time has
been accepted.
5. Enter the date using the first row of selector keys (add a leading "0" if necessary):
Press two digits for the month, press two digits for the date, and then press two
digits for the year. The master station automatically returns to normal mode.
Reboot Entire System – This triggers a "soft reset." It is similar to resetting the system
by powering it down (often known as a "hard reset"), but power is not removed from
the system. System programming information will not be lost when this function is
performed. NOTE: This function resets calls placed on the system that were not
activated by a physically latching switch and must therefore only be performed
1. Press the talk (gray) button for 7–10 seconds, until the LED on the reset
if the system has no calls pending!
(black) button is lit.
2. Press the reset (black) button.
Restore Local Database – This causes the master station to obtain programming in-
formation from the central equipment. This feature must only be used if the master
station was used on a different system or is a new/replacement master, and needs to
be updated with local system information. This process is carried out automatically
when a new master station is connected to the system and is assigned an address.
1. Press the talk (gray) button for 7–10 seconds, until the reset (black) button's
LED is lit.
2. Press the page (violet) button. The database upload takes up to five minutes,
depending upon system size. Master station control returns automatically.
Detect System Stations – This causes the system to check for added or removed stations
on the system, after which it will reboot.
1. Press the talk (gray) button for 7–10 seconds, until the LED on the reset
(black) button is lit.
2. Press the staff (green) button.
IL715 Tek-CARE
NC300II Manual • 51
®