Panel And Standard Remote Mount Unit Installation And Removal - Garmin GTX 3X5 Series Installation Manual

Hide thumbs Also See for GTX 3X5 Series:
Table of Contents

Advertisement

4.8
Panel and Standard Remote Mount Unit Installation
and Removal
CAUTION
THE APPLICATION OF HEX DRIVE TOOL TORQUE MORE THAN 8 IN-LBS CAN DAMAGE THE LOCKING
MECHANISM.
NOTE
When a unit is installed make sure it successfully powers up. For configuration procedures refer to
section 6.
NOTE
Before placing the unit in the rack, in order to make sure the position of the retention mechanism is
correct, it can be necessary to insert the hex drive tool into the access hole and turn the hex drive tool
counterclockwise until it fully stops.
Insertion
1.
Slide unit in until it stops, approximately 3/8 inch short of the final position.
2. Insert a 3/32" hex drive tool into the access hole at the bottom of the unit face.
3. Push on the left side of the bezel and turn hex drive tool clockwise and apply 8 in-lbs of torque.
Removal
1.
Insert the hex drive tool into the access hole on the unit face.
2. Turn hex drive tool counterclockwise until the hex drive tool stops.
3. Pull the unit from the rack.