Docking Station - Follett Horizon series Installation Instructions Manual

For ice manager diverter valve
Table of Contents

Advertisement

3.2
Undercounter installation requirements
Top View
Access panel/
door on counter

DOCKING STATION

• Position and screw louvered docking assembly to the bottom of counter inside of access panel/
door min. of 1.75" (45mm) from the front edge of the cross brace
• The mounting surface for the louvered docking assembly must be solid.
Do not mount directly onto runners or channels.
• There must be no lip or edge that would hinder the ice machine from sliding in or out of the
louvered docking station
• Ice machine must be installed facing forward as shown for service accessibility
ICE MANAGER
1.75" (45mm) min.
remote condensing
24.5" min.
(623mm)
21" min.
(534mm
No Lip
7