provide
additional reserve.
B.Program wheel is not rotating with meter
B.Pull cable out of
output.
meter cover and
rotate manually, program
wheel must move without
binding and clutch must give
positive "clicks"
when program wheel strikes
regeneration stop (if not, replace
timer).
C.Meter is not measuring flow. C.Check output by observing
rotation
of small gear on front of timer
(program wheel must not be against
regeneration stop for this check)
each tooth to tooth is approximately
30 gallons (if not, replace meter).
Model 5600 & 5600 Econominder®
Model 5600SF Troubleshooting
PROBLEM
CAUSE
CORRECTION

1.Filter fails to backwash.

A.Electrical service to unit has been A.Assure permanent
interrupted.
electrical service
(check fuse, plug, pull chain or
switch).
B.Timer is defective. B. Replace timer.
Power failure.
C.Reset time of day.
2.Filter "bleeds" iron.
A.Bypass valve is open.
A.Close bypass valve.