System Settings - HITEC X1RED Instruction Manual

Ac-idc-input, professional balance charger/discharger, multi charger, li-po 1-6 cell, li-hv 1-6 cell, li-fe 1-6 cell, li-ion 1-6 cell, ni-cd 1-15 cell, ni-mh 1-15 cell, pb 2-20 v
Table of Contents

Advertisement

Available languages

Available languages

System Settings

When powered on for the first time, your X1 RED charger
G
will load with default values in the programmable user
settings. The screen displays the following information
in sequence and the user can change the value of the
parameters on each screen.
Item
SYSTEM SETUP
DC Input:
Cut Caps:
Cut Time:
Cut Temp:
SYSTEM SETUP
DC Input:
Cut Caps:
Cut Time:
Cut Temp:
SYSTEM SETUP
DC Input:
Cut Caps:
Cut Time:
Cut Temp:
SYSTEM SETUP
DC Input:
Cut Caps:
Cut Time:
Cut Temp:
SYSTEM SETUP
Unit:
Resting:
Delta Peak:
Bal. Connection:
28
Selection
11.0V
5000mAH
10-12V
120min
50
C/122
F
0
0
11.0V
5000mAH
OFF/(100-5000 mAh)
120min
50
C/122
F
0
0
11.0V
5000mAH
OFF/(1-720 Min)
120min
50
C/122
F
0
0
11.0V
OFF/(200C/680 F -
5000mAH
800C/1760F)
120min
50
C/122
F
0
0
Celsius
Celsius
10 Min
Fahrenheit
4mV
ON
AC/DC-Input, Professional
Balance Charger, Discharger, Multicharger
When you are ready to change the parameter values in
the program, press START/ENTER to make it blink, and
then select the appropriate values with INC or DEC. Store
the value by pressing START/ENTER once.
Description
Users can change the DC Input low voltage warning as
necessary. The default value is 11.0V
This program sets the maximum charge capacity
that will be supplied to the battery during a charge.
If the delta peak voltage is not detected nor has the
safety timer expired for any reason, this feature will
automatically stop the process at the selected capacity
value. Default is 5000mAh.
When starting a charge process, the built-in safety
timer automatically runs at the same time.This is pro-
grammed to prevent the battery from overcharging if it
proves to be faulty or if the termination circuit cannot
detect that the battery is fully charged. The value for
the safety timer should be generous enough to allow a
full charge of the battery. Default is 120min.
Chemical reactions in the battery cause it to heat
up during charging/discharging If the specified tem-
perature threshold, which can be measured with an
optionally available temperature sensor, is reached, the
charging procedure is automatically stopped.
Display the temperature in
Celsius or Fahrenheit.