Advanced System Set Up

The system will be set to its default parameters when powered on for the fi rst
time. The screen displays the following information in sequence and the user can
change any given value on each screen.
To change a parameter value in the program, press START/ENTER to make that
value blink. Next, change the value by pressing INC or DEC. The value will be
stored by pressing START/ENTER once.
Item
Safety
Timer
ON
120 Min
Capacity Cut-Off
ON
Temp Cut-off
ON
50
0
C 122
Temperature Unit
Rest Time
CHG > DCHG 10Min
24
Selection
OFF/ON
(1-720 Min)
Default: 120 min
OFF/ON
(100-50000mAh)
5000mAh
Cut-off : 5000mAh
OFF/ON
(20
C/68
0
0
0
F
80
C/176
0
Celsius
Fahrenheit
Celsius
1-60 Min
When you start a charge process, the integral
safety timer automatically starts running at
the same time. This is programmed to prevent
overcharging of the battery if it proves to be
faulty, or if the termination circuit cannot detect
the battery full. The value for the safety timer
should be generous enough to allow a full
charge battery.
This program sets the maximum charge
capacity that will be supplied to the
battery during charge. If the delta peak
voltage is not detected, the safety will
automatically stop the process at the
selected capacity value.
The battery's internal chemical reaction
will cause the temperature of the battery
F -
to rise. If the temperature limit is reached,
F)
0
the process will be terminated.
You can choose the temperature
displayed by Celsius or Farenheit as
you like.
A rest time allows the battery to
cool down between charging/
discharging cycle.