Waeco CombiCool CAB-40B Operating Manual page 27

Absorption cooler
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 18
cab-40_40B_55.book Seite 27 Mittwoch, 29. August 2007 12:26 12
CombiCool
➤ To switch off the cooler, first close the valve on the cylinder and then
turn the gas control (2 1, page 3) towards "0".
Replacing the gas cylinder
Change the gas cylinder in a well-ventilated location.
Ensure that there are no open flames in the vicinity.
Only replace the gas cylinder when the cooler is switched off.
➤ Completely close the valve on the gas bottle.
➤ Switch off the cool box by turning the gas control (2 1, page 3) to the "0"
position.
➤ Unscrew the pressure regulator from the bottle.
➤ Check the condition of the hose line.
Replace the hose line if the material is brittle or porous.
➤ Tightly screw the pressure regualtor onto the new cylinder.
6.4
Defrosting the cooler
Humidity can form frost in the interior of the cooler. This reduces the cooling
capacity. Therefore, defrost it before this happens.
Caution
Never use hard or pointed tools to remove ice or to loosen objects
which have frozen in place.
To defrost the cooler, proceed as follows:
➤ Take the contents out.
➤ If necessary, put them in another cooling device.
➤ Switch the cooler off.
➤ Leave the cover open.
➤ When everything has defrosted, empty the cooler and wipe it out.
6.5
Switching off and storing the cooler
If you do not intend to use the cooler for a long time, proceed as follows:
➤ Switch the cooler off.
➤ Disconnect the power supply or the hose line to the gas cylinder.
➤ Clean the cooler (see "Cleaning and maintenance" on page 28).
➤ Leave the lid open.
This prevents odours from forming.
Using the cooler
27