4-6 DIGI-SEL ADJUSTMENTS

• Touch [DSEL ALL] on the main menu screen.
ADJUSTMENT
ADJUSTMENT ITEM DISPLAY
PREPARATION
1 –
DIGI-SEL
2 DIGI-SEL ALL adjustment menu –
ADJUSTMENT
3
• After the adjustment, the transceiver shows the DIGI-SEL ALL adjustment menu.
• Push [EXIT] to return to the menu screen.
SETTING CONDITION
• No test equipment is connected to
neither [ANT1] and [ANT2].
4-7
OPERATION
Touch [DIGI-SEL ALL] to start
the DIGI-SEL adjustment.
Touch [SET].
(Two beeps sound 50 minutes
later.)