Operating Mode Features - Allen-Bradley 1734-IJ User Manual

Encoder/counter modules
Table of Contents

Advertisement

Operating Mode Features

The following table summarizes which features are active in each
mode:
Operating Feature
Preset
Rollover
Software Reset
Store Count - Z Gate / Reset 4 modes
Scale Input Count at Z Gate / Reset
Z Gate / Reset Invert Bit
Sample Period
Operating Mode Features
The Z Gate/Reset Terminall will operate in one of four modes when
the Store Count feature is in use. The following figures detail the
operation in each mode:
• Store/Continue
• Store/Wait/Resume
• Store-Reset/Wait/Start
• Store-Reset/Start
Store Count Mode 1: Store/Continue
In mode 1, the rising edge of a pulse input on the Z Gate/Reset
terminal causes the current counter value to be read and stored in the
Read Data file. The counter continues counting. The stored count is
available in the Stored/Accumulated Count word. The stored count
information remains until it is overwritten with new data.
Store/Continue
Read, Store Count,
and Continue Counting
Store Count Mode 2: Store/Wait/Resume
In mode 2, the rising edge of a pulse input on the Z Gate/Reset
terminal reads and stores the current counter value in the
AB Drives
Stored/Accumulated Count word and inhibits counting while the Z
Counter
Encoder
Period
Up / Down
X1, X2 & X4
Y
Y
N
Y
Y
N
Y
Y
Y
Y
Y
N
N
N
Y
Y
Y
Y
N
N
N
Publication 1734-UM006B-EN-P - August 2005
About the Modules
1-9
Rate
/Rate
Measurement
N
N
Y
N
N
N
Y