Output overload or short circuit ....................... 16 4.3.3 Overheating ............................. 16 4.3.4 Under and over voltage ........................16 Maintenance ..............................16 Problem solving ..............................16 January 2015 / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / EN...
Page 3
Miscellaneous ..............................37 Dimensions ............................... 38 Characteristics ..............................40 ORDERING INFORMATION ............................42 EC DECLARATION OF CONFORMITY ........................43 EN / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / January 2015...
36012200 Mass Combi 12/2200-100 / 230V 36021800 Mass Combi 24/1800-35 / 230V 36022600 Mass Combi 24/2600-60 / 230V For other models see other manuals available on our website: www.mastervolt.com January 2015 / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / EN...
Check the wiring and connections at least once a year. Defects such as loose connections, burned cables etc. must be corrected immediately. EN / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / January 2015...
Avoid short circuiting batteries, as this may result in explosion and fire hazard. Installation of the batteries and adjustments of the Mass Combi should only be undertaken by authorised personnel! January 2015 / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / EN...
The three-step Plus charge system is also safe for all the connected equipment. See also section 9.5 for detailed characteristics of the three step Plus charge system. EN / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / January 2015...
The energy saving from your batteries is approximately 10%. For detailed specifications see section 9.1 “DC no load power consumption” Table 1: Mass Combi energy saving modes January 2015 / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / EN...
See figure 6. Here the Power Sharing level is set to a 6 Amps while the AC outputs consume a total of 1 + 3 = 4 Amps. This EN / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / January 2015...
By default the Generator / mains support function is disabled. It can be enabled by means of the DIP-switches (see section 6.2.3) January 2015 / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / EN...
AC, while the SHORT BREAK incoming AC. output is connected to the output of the inverter. Table 2: Overview of the AC operationmodes * see chapter 6 for adjustment of the DIP-switches EN / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / January 2015...
The ICC panel provides the same functions as the user cable panel on the Mass Combi. However, with this remote panel you have the convenience to operate the Mass Combi remotely. Figure 10: BATTERIES Parallel operation January 2015 / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / EN...
A well-lit LCD screen also displays direct online data or historical information. A protective back box, easy to install, is included as standard for protecting the electronic components. EN / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / January 2015...
4.2.1 Switching on charger regulation will all function automatically. The Mass Combi can be activated by switching the main switch to the “ON” position. January 2015 / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / EN...
DC-input and serious over voltage Close the connection compartment again. (>265VAC) on the AC-input or AC-outputs. Connect the Mass Combi to the power sources again. Switch on the Mass Combi. (see section 4.2) EN / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / January 2015...
The DC-input of the Mass Combi is also, within limits, protected against over under voltage. specifications in section 9.1. The Mass Combi switches off if the DC-input voltage is out of range. January 2015 / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / EN...
Do not locate the Mass Combi in the same compartment as the batteries. Do not install the Mass Combi straight above the batteries because of possible corrosive sulphur fumes EN / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / January 2015...
See section 9.1 Specifications for recommended fuses. To enable this automatic connection, see section 6.1.5 The fuse with the fuse-holder is available from your local Mastervolt distributor or Customer Service Representative. January 2015 / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / EN...
Philips screw driver to open the connection area of the Mass Combi Figure 20: Modular communication cable, 8 pole, cross wired. For communication between two Mass Combi’s (parallel operation) EN / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / January 2015...
AC output Positive battery SHORT BREAK terminal Cable glands Cable glands for for AC wiring main DC wiring Grommets for wiring of remote panels Figure 22: Overview connection compartment January 2015 / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / EN...
Continue with section 5.8.1 for wiring instructions of one Mass Combi in stand-alone operation or section 5.8.2 for wiring instructions of two Mass Combi’s in parallel operation. EN / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / January 2015...
Page 22
This schematic is to illustrate the general placement of the Mass Combi in a circuit. It is not meant to provide detailed wiring instructions for any particular electrical installation. Figure 24: installation drawing for one Mass Combi (stand-alone operation) January 2015 / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / EN...
Integrate a 25 Amps–T fuse in this wire. The negative pole of this battery must be connected to the negative pole of the service battery. Continue with section 5.8.3 EN / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / January 2015...
Page 24
This schematic is to illustrate the general placement of the Mass Combi in a circuit. It is not meant to provide detailed wiring instructions for any particular electrical installation. NOTE: See also section 6.1.1 for DIP-switch settings Figure 25: installation drawing for two Mass Combi’s (parallel operation). See also figure 26 January 2015 / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / EN...
(see chapter 7). See figure 26, reference . Run the modular 8-pole communication cable between Mass Combi “A” and Mass Combi “B”. Connect this cable to the PARALLEL connectors. EN / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / January 2015...
Continue with chapter 6 for DIP-switch settings See Figure 27. The alarm contact is switched to “Normally Open” in case of an alarm situation, see section 3.6. Maximum switching current: 1 Amp. January 2015 / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / EN...
SW1= ON) then its settings SW6 to SW7 of DIP switch A are denied. 6.1.2 Output frequency inverter 230V Models DIP switch A If you want… to set the output frequency to 50 Hz to set the output frequency to 60Hz EN / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / January 2015...
Neutral wire (N) of the inverter output circuit connected to the Safety Ground (PE / GND) when the Mass Combi is working as an inverter and disconnected when incoming AC-power is applied (charger / transfer mode). January 2015 / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / EN...
To set the frequency window for the incoming AC power at 35Hz < f < 65Hz CAUTION! Adjustment of the frequency window at a too low level may cause damage to the connected AC-load. Refer to the AC-input specifications of the connected loads. EN / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / January 2015...
An equalizing charge can be necessary after very deep discharges and/or inadequate charges. This has to be carried out according to the specifications of the manufacturer of the batteries. If you want… DIP switch B To start the equalize mode Off-On-Off pulse January 2015 / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / EN...
To reinstall the Mass Combi, follow the instructions as occur and avoid having flammable materials described in chapter 5. close by. Now the Mass Combi is ready for operation. EN / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / January 2015...
3 = solid yellow DC voltage error. The battery Check the batteries. 8 = solid red voltage is too high or too low. January 2015 / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / EN...
Page 33
If you cannot solve a problem with the aid of this table, contact your local Mastervolt Service Centre. See www.mastervolt.com. Make sure you have the following information present if you have to contact your local Mastervolt Service Center to solve a problem: Article and serial number (See section 1.6)
Flashes 0 times Flashes 5 times Flashes 2 times 2 . 0 Software version Software version: 1 . 3 Figure 30: Representation of the software versions of the Mass Combi January 2015 / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / EN...
= 25˚C, cos phi = 1) Load power factor range All power factors allowed Protections Over temperature, overload, short circuit, AC on output, high battery, low battery. * Adjustable by means of MasterAdjust software EN / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / January 2015...
Mix of conventional and forced air cooling, by DC fans with variable speed. Fan operation The fan does operate on a temperature and load control related PWM variable speed control. DC maintenance free fan. *** See also section 9.4 EN / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / January 2015...
156 [6.1] 300 [11.8] 242 [9.5] Figure 31: Dimensions in mm [inch] of the Mass Combi 12/1600-60 and 24/1800-35 Figure 32: Dimensions in mm of the MasterBus – Combi interface January 2015 / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / EN...
Page 39
118.5 [4.7] 39 [1.5] 110 [4.3] 128 [5.0] 140 [5.5] Figure 34: Dimensions in mm [inch] of the mounting box of the ICC remote panel and the APC remote panel EN / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / January 2015...
4 hr timer: 8 hr every 336 hr bulk timer = current Figure 36: Charge characteristic of the three-step Plus charging method for the 12V combi (@ 25°C / 77°F) January 2015 / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / EN...
Page 41
Battery Charging is not allowed above +55°C and below –20°C 12 Volt system: –30mV/°C 24 Volt system: –60mV/°C 48 Volt system: –120mV/°C Figure 38: Temperature compensation characteristic (charge voltage versus temperature) EN / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / January 2015...
** These parts are delivered as option with the delivery of the Mass Combi Mastervolt can offer a wide range of products for your electrical installation, including automatic AC transfer switches, remote control panels and DC distribution kits. See our website www.mastervolt.com for an extensive overview of all our products...
EN 61000-6-3: 2007 Emission for residential, commercial and light-industrial environments EN 61000-6-2: 2007 Immunity for industrial environments 2011/65/EU (RoHS directive) Amsterdam, 16 January 2015 H.A. Poppelier Manager New Product Development EN / Mass Combi 12/1600-60; 12/2200-100; 24/1800-35; 24/2600-60 / January 2015...