5 E m e r g e n c y K e y s a n d A l a r m s

5.3 Carbon Monoxide Alarm - 4 beeps, long pause, 4 beeps

WARNING:
Carefully review your Carbon Monoxide Alarm Installation/User Guide to determine the
necessary actions required to ensure your safety and ensure that the equipment is operating
correctly. Incorporate the steps outlined in the guide into your evacuation plan.
Activation of your CO alarm indicates the presence of carbon monoxide (CO), which can be fatal. During
an alarm:
• The red LED on the CO detector flashes rapidly and buzzer sounds with a repeating cadence of:
4 quick beeps, 5-second pause, 4 quick beeps.
• The siren connected to the control panel produces the same cadence as above.:
• The keypad provides audible and visual indication of the CO alarm.
If the Carbon Monoxide Alarm Sounds
1. Operate silence button.
2. Call emergency services or your fire department.
3. Immediately move outdoors or to an open door/window.

5.4 Resetting Sensors

After having detected an alarm condition certain sensors require a reset to exit the alarm condition (i.e.
glass break sensors, smoke detectors, etc.).
NOTE:
Verify with your alarm company if this function is required on your system.
To Reset the Sensors
• Press and hold
celled.
• If a sensor fails to reset, it may still be detecting an alarm condition. If unsuccessful, the alarm will
reactivate or continue.

5.5 Viewing Alarms in memory

When an alarm occurs the keypad indicator illuminates. Viewing the Alarm memory provides more
information on the sensor(s) that were tripped.
To View Alarms in Memory
*
• Press
3
OR
use the scroll keys
The Alarm information will display. For more information on the messages
that could be displayed see 5.5.1 "Alarm Messages".

5.5.1 Alarm Messages

What you see
Burglary
<>
Verified
Burglary Not
<>
Verified
Fire Alarm
<>
Fire Zone 1
CO Alarm
<>
CO Zone 1
<>
on the keypad for 2 seconds. If the sensor reset is successful, the alarm is can-
to navigate to Alarm Memory and press
What it means
Multiple burglary sensors were tripped. Central station has been notified.
A single burglary sensor was tripped. Central station has been notified.
Fire alarm has been triggered. Central station has been notified.
CO alarm has been triggered. Central station has been notified.
18
What you see
Press (*) for <>
Alarm Memory
*
.