Mitsubishi Electric DeviceNet FR-E5ND Instruction Manual page 63

Transistorized inverter, option
Table of Contents

Advertisement

6.8.3 Class 0x66 Instance Attributes Instance 1
(Please refer to the relevant E500 Instruction Manual for parameter details)
(Pr. 0 = #10)
#
Access
10
Get/Set
Pr. 0
11
Get/Set
Pr. 1
12
Get/Set
Pr. 2
13
Get/Set
Pr. 3
14
Get/Set
Pr. 4
15
Get/Set
Pr. 5
16
Get/Set
Pr. 6
17
Get/Set
Pr. 7
18
Get/Set
Pr. 8
19
Get/Set
Pr. 9
20
Get/Set
Pr. 10
21
Get/Set
Pr. 11
22
Get/Set
Pr. 12
23
Get/Set
Pr. 13
24
Get/Set
Pr. 14
25
Get/Set
Pr. 15
26
Get/Set
Pr. 16
28
Get/Set
Pr. 18
E500 Parameters
Attribute
Torque Boost
Maximum Frequency
Minimum Frequency
Base Frequency
Multi Speed Setting (High Speedj
Multi Speed Setting (Middle Speed)
Multi Speed Setting (Low Speed)
Acceleration Time
Deceleration Time
Electronic Thermal O/L Relay
DC Injection Brake Operation Frequency
DC Injection Brake Operation Time
DC Injection Brake Voltage
Starting Frequency
Load Pattern Selection
Jog Frequency
Jog Acceleration/Deceleration Time
High Speed Maximum Frequency
54
OBJECT MAP
Default Value
(Note 2)
120.00 Hz
0.00 Hz
60.00 Hz
(Note 2)
30.00 Hz
10.00 Hz
(Note 2)
(Note 2)
(Note 2)
3.00 Hz
0.5 s
6.0 %
0.50 Hz
0
5.00 Hz
0.5 s
(Note 2)

Advertisement