Mitsubishi Electric DeviceNet FR-E5ND Instruction Manual page 70

Transistorized inverter, option
Table of Contents

Advertisement

#
E500 Pr.
47
Pr. 347
48
Pr. 348
#
E500 Pr.
202
Pr. 902 Freq
203
Pr. 902 %
204
Pr. 903 Freq
205
Pr. 903 %
206
Pr. 904 Freq
207
Pr. 904 %
208
Pr. 905 Freq
209
Pr. 905 %
Note 1: Parameters marked "Special" should not be changed under normal operating conditions. Improper inverter
operation and damage to equipment may occur.
Note 2: Some default values depend on the capacity, voltage and type (i.e. EC, NA) of inverter.
Note 3: The default values 65535, 6553.5 Unit, 655.35 Unit simply indicate the function is NOT Active. These settings
will be reflected as "9999" when viewed via the inverter parameter unit.
Access
Get/Set
DeviceNet mode address data (Higher byte)
Get/Set
DeviceNet baud rate data (higher byte)
Calibration Functions
Access
Get/Set
Frequency Voltage Bias - Frequency
Get/Set
Frequency Voltage Bias - Percent
Get/Set
Frequency Voltage Gain - Frequency
Get/Set
Frequency Voltage Gain - Percent
Get/Set
Frequency Current Bias - Frequency
Get/Set
Frequency Current Bias - Percent
Get/Set
Frequency Current Gain - Frequency
Get/Set
Frequency Current Gain - Percent
61
Attribute
Attribute
OBJECT MAP
Default Value
160
80
Default Value
0.00 Hz
0.0 %
60.00 Hz
97.0 %
0.00 Hz
18.8 %
60.00 Hz
92.7 %