6.4.5 Class 0x05 Instance Attributes Instance 3 - Explicit Messaging
#
1
2
3
4
5
6
7
8
9
12
13
14
15
16
Access
Attribute
Get
State
Get
Instance Type
Get
Transport Trigger Class
Get
Produced Connection ID
Get
Consumed Connection ID
Get
Initial Comm Characteristics
Get
Produced Connection Size
Get
Consumed Connection Size
Get
Expected Pack Rate
Get
Watchdog Action
Get
Produced Connection Path Length
Get/Set
Produced Connection Path
Get
Consumed Connection Path Length
Get/Set
Consumed Connection Path
44
OBJECT MAP
Value
0 to 5
0 to 1
0x83
0 to 0x07F0
0 to 0x07F0
0x33
7
7
2504 (Default)
0 to 2
0
Variable
0
Variable