No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. Information provided in this manual is intended to be accurate and reliable. How- ever, Advantech Co., Ltd.
Page 3
Technical Support and Assistance Visit the Advantech web site at www.advantech.com/support where you can find the latest information about the product. Contact your distributor, sales representative, or Advantech's customer service center for technical support if you need additional assistance. Please have the...
Page 4
Replace only with same or equivalent type recom- mended by the manufacture. Discard used batteries according to the manufacturer’s instructions Cleaning: During normal use of the HIT-W121 may become soiled and should, therefore, be cleaned regularly. Agents: Alcohol or water.
Page 5
Note! Attention, please thoroughly consult the accompanying documentation. Caution! This product: HIT-W121 is only used with the qualified & certificated power adapter listed below: Medical: SINPRO ELECTRONICS CO LTD, model: MPU50-107, Output: 16-21Vdc, 50W max (SET UP19Vdc, 2.63A).
Chapter Introduction This chapter briefly introduces the HIT-W121 product. Overview System Configuration...
Page 10
Windows XP Embedded OS. In addition to providing hospital bedside patient information, remote monitoring, and care functions, the CPU and the LAN- enabled architecture of the HIT-W121 terminal also serves as an integrated hospital gateway device. The HIT-W121 equipped with an Intel Atom 1.6GHz Dual-core pro- cessor, 11.6"...
Chapter Hardware Description This Chapter describes the hard- ware features of the HIT-W121. General Specifications Mechanical Specifications External View...
General Specifications Operating Humidity: 20% to 90% (No Condensation) Operating Atmospheric Pressure: 700 to 1060 hPa Storage Humidity: 10% to 95% (No Condensation) Storage Atmospheric Pressure: 700 to 1060 hPa Transportation Temperature: 20 to 60 Transportation Humidity: 10% to 95% (No Condensation) Transportation Atmospheric Pressure: 700 to 1060 hPa...
Carton Dimensions: 500 (W) x 385 (H) x 160 Mounting System: VESA 75*75mm standard mounting hole Net Weight: 3 kg VESA Mount: 75*75 mm or 100*100 mm SCREWS: M4*10 mm Caution Use suitable mounting apparatus to avoid risk of injury. HIT-W121 User Manual...
10 ~ 18 Hz, 1.5 mm peak-to-peak displacement 18 ~ 500 Hz, 1 G acceleration Reliability MTBF 30,000 hours Touchscreen 10 million touch actuation times on a single point Power Requirements DC Input Voltage: 19 V Power Consumption: less than 60 W HIT-W121 User Manual...
Page 26
Annex Guidance and manufacturer’s declaration – electromagnetic emissions The model HIT-W121 is intended for use in the electromagnetic environment specified below. The customer or the user of the model HIT-W121 should assure that it is used in such an environment.
Page 27
(IEC/EN 60601-1-2:2007) Guidance and manufacturer’s declaration – electromagnetic immunity The model HIT-W121 is intended for use in the electromagnetic environment specified below. The customer or the user of the model HIT-W121 should assure that it is used in such an environment.
Page 28
RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the model HIT-W121 is used exceeds the applicable RF compliance level above, the model HIT-W121 should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the model HIT-W121.