7.9 Opening the Cover Plate of an RRU Cabling Cavity

This section describes the procedure for opening the cover plate of an RRU cabling cavity.
Procedure
Step 1 Wear ESD gloves.
Take proper ESD protection measures, for example, wear ESD gloves, to prevent electrostatic
damage to the boards, modules, or electronic components.
Step 2 Loosen the protection screw on the cover plate of the RRU cabling cavity using an M4 Phillips
screwdriver, and then lower the handle to open the cover plate, as shown in
Issue 01 (2011-12-27)
2.
Connect the other end of the AISG extension cable to the standard AISG male
connector on the RCU, as shown in
Figure 7-16 Installing an RRU AISG multi-wire cable
3.
Lay out the cable by referring to
using cable ties.
4.
Label the installed cable by referring to Attaching an L-Shaped Label.
CAUTION
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Figure
7-16.
7.1 Cabling
Requirements, and then bind the cable
7 Installing RRU Cables
Figure
7-17.