CONFIGURATION 1 BALLAST REPLACEMENT
NOTE: IF REPLACING 2 BALLASTS REPEAT STEPS 1-7 FOR SECOND BALLAST
1. Disconnect all lamps by pressing the
release tabs on connectors and gently
pulling apart.
3. Remove the 2 mounting screws and lift
the ballast from the unit. Set aside for
disposal or return.
CHOOSE THE CORRECT LAMP CONNECTOR HARNESS
Populate the output side of the new ballast with the correct lamp connector harness wires: Connect all
the color wires to the corresponding color inputs in the ballasts.
NOTE: Use only the side terminals.
H
2 Lamp unit
5. Re-attach the new ballast assembly to the mounting plate with the bulkhead connectors on the same side.
6. Attach the bulkhead connector(s).
7. Attach the lamp connector harness(es) to the lamp wires.
8. Install the bonnet with the 3 screws.
9. Turn on power to the UV unit and pump & test for system functionality.
2. Disconnect the bulkhead connector(s).
H
4. From the replacement ballast kit, connect all the
color wires of the bulkhead connector (B) to the
corresponding color inputs in the ballast(s)(H).
NOTE: Use only the side terminals.
C
H
3
1 Lamp unit
B
G

Advertisement