DANGER
Ultra UV2 Universal Ballast
Replacement Kit #005-422-9030-00
Includes:
(A)double neutral wire to terminal
(B)input bulkhead wiring harness
(C)2 lamp wiring harness
(D)ground wire
(E)single neutral wire to terminal
(F)pressure switch wire
(G)1 lamp wiring harness
(H)Ballast
(I)connector tool*

IMPORTANT NOTES

The Ultra UV2 includes ballast
input wires for several build
configurations. Not all wires
included in kit will be used.
*If wires need to be removed from
the ballast use connector tool (if
supplied in kit), slotted screwdriver
or paper clip. Insert tool into slot
and pull wire from ballast.
Remove the bonnet screws & lift bonnet from tank
and proceed to replacing ballasts.
IDENTIFY THE CONFIGURATION OF THE ULTRA UV2 UNIT
ULTRA UV CONFIGURATION 1
BULKHEAD CONNECTOR (UNITS BUILT
BETWEEN APR. 2014 TO NOV. 2018
(PAGE 3)
Turn off the power supply to the Ultra UV2 unit. Turn off power to the pool pump.
Disconnect the input power to the installed Ultra UV2:
• For 120v units unplug the supply cord from the GFCI.
• For 230v units disconnect the incoming power by switching the circuit breaker off.
A
H
E
F
D
G
ULTRA UV CONFIGURATION 2
TERMINAL BLOCK (UNITS BUILT AFTER NOV.
2018 (PAGE 4)
2
I
B
C