Download Print this page
Paramount Fitness ULTRA UV Operating Instructions Manual

Paramount Fitness ULTRA UV Operating Instructions Manual

Uv water sanitizer
Hide thumbs Also See for ULTRA UV:

Advertisement

Available languages

Available languages

Quick Links

Pool, Spa & Pond
Water Sanitizer 4BJ1
1555 Detrick Ave • Deland, Florida 32724
Toll Free: 1.866.649.5551 • Phone: 407.600.5751 •
sales@ultravioletpools.com • www.ultravioletpools.com
004-027-8709-00 REV 050814
IMPORTANT SAFETY INSTRUCTIONS:
READ COMPLETELY BEFORE PROCEEDING.
When using this electrical equipment, basic safety precautions should
always be followed, including the following:
WARNING:
• Follow all applicable electrical codes.
• Turn off power at main source before making any electrical connections
or servicing the unit.
• To reduce the risk of electric shock, injury or death disconnect unit from
power supply
• Follow the instructions or risk of serious injury or death could occur!
UV EXPOSURE & PROTECTION:
UV-A and UV-B radiation can have adverse short and long term effects on
the eyes and skin. Never look directly at a UV lamp that is connected to a
power source. Avoid UV skin exposure at all times.
EPA Registered
#084221-AZ-001
Cleaning, Replacing And
Resealing The Quartz Tube

Advertisement

loading

Summary of Contents for Paramount Fitness ULTRA UV

  • Page 1 Cleaning, Replacing And Resealing The Quartz Tube IMPORTANT SAFETY INSTRUCTIONS: READ COMPLETELY BEFORE PROCEEDING. When using this electrical equipment, basic safety precautions should always be followed, including the following: WARNING: • Follow all applicable electrical codes. • Turn off power at main source before making any electrical connections or servicing the unit.
  • Page 2 Cleaning quartz tube. The quartz tube requires cleaning every 6 months to ensure optimum performance. 1. Turn off all power to the ULTRA UV unit and all other pool equipment. Unplug the unit from its power receptacle or turn OFF the circuit breaker that is the ULTRA UV’s...
  • Page 3 YOU MUST WEAR PROTECTIVE RUBBER GLOVES. DO NOT HANDLE A HOT LAMP OR SERIOUS BURNS WILL OCCUR. DO NOT TOUCH THE GLASS PART OF THE LAMP AS BODY OILS WILL CREATE HOT SPOTS & GREATLY SHORTEN LAMP LIFE. (Fig. 11) 4.
  • Page 4 9. Inspect the quartz tube carefully for any cracks or chips and replace the quartz tube if any are found. The ULTRA UV unit is Fig. 16 supplied with 3 additional O-rings. Do not use any other O-ring at any...
  • Page 5 12. Then place the aluminum compression washer on the quartz tube. Press down on the aluminum compression washer with an even steady pressure (Fig. 20). This will roll the O-ring into the area between the inside of the black threaded sleeve and the quartz tube.
  • Page 7 FRANÇAIS ENTRETIEN DU TUBE DE QUARTZ CONSIGNES DE SÉCURITÉ IMPORTANTES: LIRE AVANT DE CONTINUER. Lors de l’utilisation de cet équipement électrique, les consignes de sécurité de base doivent toujours être suivies, y compris ce qui suit: AVERTISSEMENT: • Respectez tous les codes électriques applicables. •...
  • Page 8 équipements de la piscine. Débranchez l’appareil de son alimentation ou désactiver le disjoncteur qui est la source d’alimentation de l’appareil ULTRA UV. Avant de procéder à étape Fig. 8 2, attendre au moins 15 minutes pour que les ampoules dans l’appareil se rafraîchissent.
  • Page 9 VOUS DEVEZ PORTER DES GANTS DE PROTECTION EN CAOUTCHOUC. NE PAS MANIPULER UNE LAMPE CHAUDE OU DES BRÛLURES GRAVES POURRAIENT SURVENIR. NE TOUCHEZ PAS LA VITRE DE LA LAMPE, PUISQUE LES HUILES CORPORELLES POURRAIENT CRÉER DES POINTS CHAUDS ET RACCOURCIR CONSIDÉRABLEMENT LA VIE DES LAMPES.
  • Page 10 8. À l’aide de gants de protection en caoutchouc et des lunettes de protection, utiliser un bon nettoyeur à douche/baignoire ou une solution de vinaigre blanc et d’eau pour nettoyer l’extérieur du tube de quartz (Fig. 16). Si l’intérieur du tube de quartz est humide ou nécessite un nettoyage, utiliser la même solution.
  • Page 11 12. Ensuite, placer la rondelle de compression en aluminium sur le tube de quartz. Appuyez sur la rondelle de compression en aluminium avec une pression constante (Fig. 20). Ceci va rouler le joint torique dans la zone située entre l’intérieur de la douille filetée noir et le tube de quartz.