WPLED104 INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We'd like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
WIRING
Universal voltage driver permits operation at 120V thru
277V, 50 or 60 Hz. Units ordered with (/480V) suffix are 480V.
1. Connect the black fixture lead to the (+) LINE supply lead.
2. Connect the white fixture lead to the (-) COMMON supply
lead.
3. Connect the GROUND wire from fixture to supply
ground.
(+)LINE
(-)COMMON
GROUND

TROUBLESHOOTING

1. Check that the line voltage at fixture is correct.
2. Is there voltage at the lamp fixture wires? If there is no
voltage, check all connections.
3. Is the fixture grounded properly?
WPLED104 Cool
US: pat. D653,377; CN: ZL201130356930.8; MX: 36921; CA: D - RAB Lighting, Inc
Easy Installation & Product Help
Tech Help Line
©2013 RAB LIGHTING Inc.
Call our experts 888 RAB-1000
Northvale, New Jersey 07647 USA
WPLED104 IN 0913
BLACK
LIGHT
WHITE
FIXTURE
GROUND
WPLED104 Neutral
PHOTOCELL INSTALLATION
Photocell may be installed in the field. Apply weatherproof
silicone sealant to all plugs and unused conduit entries.
1. Remove close up plug on top of the wall mounting box.
2. Install photocell and wire as per diagram.
3. Use photocell rated for your supply voltage.
PHOTOCELL
PHOTOCELL
Note: These instructions do not cover all details or variations in
equipment nor do they provide for every possible situation during
installation, operation or maintenance.