WPLED
78W WALL MOUNT INSTALLATION INSTRUCTIONS
TM
WALL MOUNT BOX DETAILS
Wall Feed

TROUBLESHOOTING

1. Check that the line voltage at fi xture is correct. Refer
to wiring directions.
2. Is the fi xture grounded properly?
3. Is the photocell functioning properly (if used)?
4.57"
Key Hole Slot
2.4"
1.09"
3.0"
.79"
Hardware
(not supplied)
Conduit Feed
®
WIRING
Universal voltage driver permits operation at 120 to
277VAC, 50 or 60Hz.
1. Connect the black fi xture lead to the (+) LINE
supply lead.
2. Connect the white fi xture lead to the (-) COMMON
supply lead.
3. Connect the bare copper Ground wire from fi xture to
supply ground.
CLEANING & MAINTENANCE
CAUTION: Be sure fi xture temperature is cool
enough to touch. Do not clean or maintain while
fi xture is energized.
1. Clean glass lens with non-abrasive glass cleaning
solution.
2. Do not open fi xture to clean the LED. Do not touch
the LED.