FLOODINATOR

LAMP INSTALLATION

CAUTION: Prior to installing, check that the lamp is
the correct ANSI type and wattage. Observe lamp
manufacturer's recommendations on lamp operation,
ballast type and burning positions.
1. Disconnect power. Make sure fi xture and lamp are
cool enough to touch.
2. Loosen (4) screws from the door of the fi xture.
Screws will remain captive to door. Open and
swing door down on hinges.
3. Fully screw lamp into socket.
4. Before closing door, make sure door gasket is
properly seated all around the door.
5. Check that all mounting bolts are tight.
6. Close door. Tighten screws.
WIRING
All units are factory wired for 277V, except for units
with a requested 120V Photocell("/PC"). If voltages
other than 277V are required, remove ballast cover and
rewire for the appropriate voltage.
1. Connect the black fi xture lead to the (+) LINE
supply lead.
2. Connect the white fi xture lead to the (-) COMMON
supply lead.
3. Connect the Ground wire from fi xture to supply
ground.
4. All unused leads must be capped and insulated.
Supply
Note: These instructions do not cover all details or variations
in equipment nor do they provide for every possible situation
during installation, operation or maintenance.
FN-IN-0408
INSTALLATION INSTRUCTIONS
TM
REPLACEMENT LAMPS AND
BALLASTS
Wattage
High Pressure Sodium
400
1000
Metal Halide
400
400PS
1000
480V Ballasts are available, consult factory.

TROUBLESHOOTING

1. Is the proper lamp is installed? Check the wattage
2. Make sure the lamp is not defective. Try a lamp
3. Check that the line voltage at fi xture is correct. Refer
4. Is there voltage at the lamp socket? If there is no
5. Is the fi xture grounded properly?
6. Is the photocell functioning properly (if used)
ACCESSORIES
Wire Guard:
6" Hood
12" Hood
Factory Installed Photo Cells
120V Swivel
277V Swivel
480V Swivel
RAB fi xture designs are protected under
U.S. and International Intellectual Property laws.
Patent Pending
Page 3
®
RAB Lamp
Catalog#
LHPS400
LHPS1000
LMH400
LMH400PS
LMH1000
and ANSI code on the fi xture label against markings
on the lamp. Refer to Replacement Lamp table
above for verifi cation.
known to be in operating condition.
to wiring directions.
voltage, check all connections.
ANSI
RAB Ballast
Code
Catalog#
S51
BHPSH400QT
S52
BHPSH1000QT
M59
BMHH400QT
M155
BMHH400PSQ
M47
BMHH1000QT
?
GDFN
FNH6
FNH12
/PCS
/PCS2
/PCS4