To isolate your inputs, supply your own power supply to C0- (GND) and C0+ (positive voltage supply). Do not power the
C0+ with more than 48V. All the other wiring configurations (PNP, NPN, etc) are the same whether or not the inputs are
isolated. In the example below, the inputs are isolated using a separate 5V power supply.
Figure 57 5V Isolated Power Supply
7.2
Configuring Your Inputs
To configure an input, follow the procedure below.
1. On the menu bar click on Config, then Ports and Pins.
2. Select the Input Signals tab. Scroll down to the desired input. There are 4 inputs and 15 OEM triggers. An
OEM trigger acts exactly like an input. You can also use any of the inputs for limit switches.
Figure 58 Input Configuration
1. Enable the input by clicking on the red X. If the input has a green check mark, it is already enabled.
2. Set the Port Number and Pin Number to the desired input. Use the table below to set up your ports and
pins.
Input Number
X0
X1
X2
X3
X4
X5
X6
Port Number
1
1
1
1
1
2
2
Pin Number
10
11
12
13
15
10
11

Advertisement