Low Voltage Sourcing Inputs (Pnp) - MachMotion Apollo I User Manual

Mach3
Table of Contents

Advertisement

Figure 52 High Voltage Sourcing Inputs
Note: All the inputs use the same common.
Below is another example with a 12V PNP proxy sensor.
Figure 53 12V Proxy Example

7.1.3 Low Voltage Sourcing Inputs (PNP)

For 2.5-10V inputs, connect your positive voltage to the C0+ terminal and your ground to C0-. Completely remove the
jumper corresponding to the input and connect XNL (where N represents the input number) to GND. Then connect your
signal to the corresponding input.
Assuming that the jumper for X5 has been removed, the example below shows how to wire in a 5V toggle switch.