Section 3.0 Specifi cations
3M
Wrist Strap and Ground Monitor 773
Parameter
Ground Impedance Alarm Level
Wrist Strap Alarm
Body Voltage
Operator Loop Resistance
Output Signal Level
Alarm Indicators
Visual Indication (LED)
Audible
Operating Environmental Range
Dimensions
AC/DC Adapter
US 120VAC, 60Hz
Universal 100 - 230VAC 50 - 60Hz
10
Typical Value or Function
1 to 20 Ohms
+/-5 Volts on operator
10 Megohms on operator (plus two 1 Megohm
resistors in the end of the ground cord that
attaches to the wrist band)
Logic 1 (+5V) if below selected resistance level
(all "pass")
Logic 0 (0V) if above selected resistance level
(any failure or power loss)
Note: This is for both process tools and wrist
strap monitoring.
Green OK, Red Fault Condition
Note: Operator LEDs red or green will not
illuminate if wrist strap is not plugged into jack.
Buzzer fault condition if enabled is ON.
Temperature: 50°F, (10°C) to 110°F (43°C)
Humidity: 75% R.H. Maximum
2.4 in. W x 0.85 in. H x 2.25 in. L
61 mm x 22 mm x 59 mm
Output: 12VDC @500 mA
Output Plug Polarization: Center Positive
Output Plug: 5.5 mm O.D. x 2.1 mm I.D. x
2.1 mm x 9.5 mm length