10.1. Analog Outputs

The line level outputs of the M-32 DA Pro operate at +13 dBu, +19 dBu, or +24 dBu. Each individual
channel has its own line level setting, which can be adjusted remotely. Additionally, channels can be
muted globally or individually.
In its default state, no routing exists between the digital inputs and the analog outputs. Each group of
four consecutive outputs can receive its signal from any digital input that is connected and
synchronized.
At all sample rates, the converters operate with short delay IIR filters. At single speed, a short delay
'sharp' filter is used to ensure linear frequency response. At double and quad speed, a short delay 'slow'
filter is used to optimize the transient response of the M-32 DA Pro while maintaining linear frequency
response in the audible range.
The resulting latencies are 7 samples at single speed and 5.5 samples at sample rates > 48 kHz.

10.1.1. Adjusting the Output Line Level

To adjust the output line level:
1. Open the Analog Output Configuration tab in the OUTPUT section.
2. Initially, the cursor will highlight all output channels. To accept this, rotate the encoder to move the
cursor to the current reference level.
3. Alternatively, pressing the encoder on the channel strip allows the selection of an individual channel.
Cursor (current channel)
Input Reference Level
Channel Mute
4. Move the cursor to the current line level and push it.