Using A Cable Coupler As An Interface Between Different Types Of Cable - Bosch DICENTIS Hardware Installation Manual

Hide thumbs Also See for DICENTIS:
Table of Contents

Advertisement

36
en | Installation material and tools
Installation in a floor pod as break-out box
5.5.3

Using a cable coupler as an interface between different types of cable

The cable coupler can be used as an interface between DICENTIS cable and "standard"
CAT-5E cable, optionally combined with a separate power cable. This can be used, for
example, when standard CAT-5E cabling coming from the technical room has to be connected
with DICENTIS cable in the conference room.
To set this up:
1.
2.
3.
4.
Warning!
Risk of electric shock. Exposed power cables are a potential hazard. Make sure all power
!
cables are securely fastened by fixing them with a tie wrap on the inside of the box (see
drawing 'Creating a tension relief').
5.
Note:
2018.09 | V1.8 |
DCNM-(A)PS
Open the housing of the cable coupler.
Connect the power cables to the screw terminals + and -.
Remove the break-out of the housing to guide the power cables through.
Create a tension release.
Close the housing and fix the screw with torque 0.4 Nm.
The cable length is not allowed to exceed 100 m.
No more than 2 cable couplers can be used in one trunk.
Hardware Installation Manual
DICENTIS
Bosch Security Systems B.V.

Advertisement

Table of Contents
loading