CCS 1000 D Digital Discussion System Release Notes
4. Upgrade the Control unit with:
CCSD-CU-enable-upgrade-1.70-1.72.bin
5. Upgrade the Control unit with the latest software you downloaded in step 1:
CCSD-CU-upgrade.bin

4 Known issues

4.1 Manage recorder page becomes slow after many recordings

Issue:
When there are a lot of recordings stored loading the Manage recorder page loads slower since
information about all these recordings needs to be loaded.
Solution:
Delete redundant recordings to decrease the loading time of the Manage recorder page.

4.2 Security check reports vulnerability

Issue:
Security check results in Nginx version 1.5.6 – CVE-2014-0133 flag. The vulnerability concerns
the spdy module which is part of this Nginx version.
Solution:
Our product uses Nginx version 1.5.6 without the mentioned ngx_http_spdy_module module.
Because the software does not include the affected module, this vulnerability is not present.
Issue:
Security check results in Nginx version 1.5.6 – CVE-2021-23017 flag. The vulnerability concerns
usage of the "resolver" directive in the configuration file.
Solution:
Our product uses Nginx version 1.5.6 without using the "resolver" directive. Because the software
does not use the "resolver" directive, this vulnerability is not present.

4.3 ONVIF camera authentications are not shown in the web browser

Issue:
ONVIF camera authentication e.g. user name and password changes are not reflected
immediately on camera settings page when you enable/disable the authentication settings in the
ONVIF camera.
Solution:
Reboot the camera or reboot the CU.

4.4 Sony or Panasonic in disconnected state

Issue:
Sony or Panasonic camera is showing the thrash icon when changing the network settings of the
CU are changed from receive IP address automatically to fixed IP address or vice versa.
Solution:
Reboot the CU.

4.5 Sony SRG-300SE is seen as fixed camera

Issue:
Sony SRG-300SE is seen as fixed camera after upgrading to 1.7 software.
To support the new Sony cameras like the BRC-X400 the supported authentication method is
changed from Basic authentication to Digest authentication in version 1.7.
Solution:
1. Change the authentication mode of the Sony camera from Basic authentication to Digest
authentication via the web browser of the camera.
2. Delete the camera from the configuration.
3. Add the Sony camera to the configuration.
4. Assign the seats to the Sony camera again.