DICENTIS
5
Installation material and tools
This section describes installation material such as cables, connectors and tools.
Recommedations
–
–
–
Warning!
Do not exceed the bend limitations of system network cables (DCNM‑CBxxx):
!
The minimum bend radius of the system network cable is a 35 mm radius.
5.1
DICENTIS System Cable Assemblies
The DICENTIS System Cable Assemblies, terminated with connectors on both ends, are
available in different lengths and are used to connect DICENTIS devices to each other. The
cable consists of a low smoke zero halogen solid core.
Ordering number
DCNM-CB02-I
DCNM-CB05-I
DCNM-CB10-I
DCNM-CB25-I
Tab. 5.6: Cable types and lengths
Figure 5.1: DCNM-CBxx-I cable and connector view
Bosch Security Systems B.V.
Always use manufacturer specified installation products, materials and tools.
In general, use different cable ducts for the system network cables, audio cables and
mains supply cables.
In public areas where people can touch or move above the connectors and cables, use
metal protection covers.
Hardware Installation Manual
Installation material and tools | en
Cable lengths
m
2
5
10
25
31
ft
6.56
16.40
32.81
82.02
2018.09 | V1.8 |