Henny Penny 500 Operator's Manual page 73

Pressure fryers with computron controls
Hide thumbs Also See for 500:
Table of Contents

Advertisement

Display
"E-6A"
Temperature probe open.
"OIL PROB OPEN"
"E-6B"
Temperature probe shorted.
"OIL PROB SHRT"
"E-10"
High limit.
"HIGH LMT TRIP"
"E-15"
Drain switch failure.
"DRAIN IS OPEN"
"E-20C" (SSI Gas
Ignition module(s) failure.
Fryers Only)
"E-20D" (SSI Gas
No ignition.
Fryers Only)
"E-41"
Programming failure.
"E-46"
Programming failure.
"E-70A"
Missing or broken wire in pins 1
and 2 of P11 connector, or faulty
connector.
Faulty I/O board.
Cause
and temperature probe should be
checked.
Turn switch to off position, then
turn switch back to on; if display
shows "E-6", have the tempera-
ture probe checked.
Turn switch to off position, then
turn switch back to on; if display
shows :E-6", have the tempera-
ture probe checked.
Reset the high limit by manually
pushing up on the reset button; if
high limit does not reset, high lim-
it must be replaced.
Close drain, using the drain valve
handle; if display still shows "E-
15", have the drain microswitch
checked.
Turn switch to off, then back to
cook to try the ignition process
again; if "E-20C" persists, have
ignition modules.
Turn switch to off, then back to
cook to try the ignition process
again; and if "E-20D" persists,
have gas valve and gas flow
checked/
Turn switch to off, then back to
cook; if display shows any of the
error codes, try to reinitialize the
control ; if error code persists,
have the control board replaced.
Turn switch to off, then back to
cook; if display shows any of the
error codes, try to reinitialize the
control ; if error code persists,
have the control board replaced.
Have jumper wire between pins 1
and 2 checked.
Have I/O board checked and re-
placed, if necessary.
Correction
61

Advertisement

Table of Contents
loading

This manual is also suitable for:

561600

Table of Contents