Star t / Stop a Sequence
Step 1:
N o t e :
D i m m e r C u r v e s
SmartPack is capable of dimming multiple load types including incandescent, low voltage
and 2-wire fluorescent. SmartPack provides five user-selectable dimmer output curves to
choose:
IES modified square law
Linear
Switched (50% threshold, non-regulated)
Fluorescent with adjustable cut-off
Adjustable pre-heat
Set Dimmer Curve
Step 1:
Step 2:
Step 3:
12
Scroll to Sequencer, press
• Start the sequence, scroll to Start Sequence and press
Started will briefly display and the control symbol on the LCD will display
the "S".
The sequence will start at preset 1 and run for a user configured number of steps.
If the sequence is not configured to loop, the sequence will stop. If the sequence
is set to loop, the sequence will continue looping until the sequence is deactivated.
• Stop the sequence, scroll to Stop Sequence and press
Stopped with briefly display and the control symbol on the LCD will no
longer display the "S".
Scroll to Dimmer Curves, press
Use + or - to select the specific dimmer number (or ALL) to be modified. Press
Use + or - to scroll through the five options, press
choice.
a: If Fluorescent output curve is selected you must specify the Start Voltage.
• Fluorescent circuits provide a dimmable output in the 5% to 100% control
range. Trim the minimum RMS output voltage to match your specific
ballast.
• The default voltage is 47% of your mains voltage. Use + or - to increase or
decrease the Start Voltage value.
• Consult the ballast manufacturer's documentation for the appropriate
minimum start voltage.
b: If Preheat output curve us selected you must specify the preheat level
(allowable 0% - 20% range).
.
.
to select the output curve of