L C D D i s p l a y
The display is a high contrast 20-character by two line backlit LCD. The control symbol,
indicated in the top right corner of the LCD, indicates the current control source.
DMX: 001 > 012
Level:
N o t e :
When configuring the SmartPack:
Characters or [TEXT] in brackets indicate an item can be selected
Characters or >Text< in angle brackets indicate an item is selected
Adjusting the Contrast of the LCD Display
Press and hold << and use the + and - buttons to adjust the contrast of the LCD display.
I n i t i a l P o w e r U p D i s p l a y
The first time you apply power to the SmartPack you will be asked to choose a language
for the operating system. The language options will cycle through the following four options
at three second intervals.
Set Language - English
Choisir la langue - Français
Sprache auswählen - Deutsch
Seleccionar idioma - Español
M e n u L o c k o u t
The menu lockout function restricts users from performing any changes to the current
operation of the SmartPack from the facepanel. When lockout is enabled the emergency
contact input, SmartLink station control, and incoming DMX levels will still affect change in
the output level of the Smartpack dimmers. Set levels from the test menu prior to engaging
lockout will be held until lockout has been disengaged.
To engage menu lockout:
Press and hold + and - buttons for a period of 5 seconds.
When lockout is on, all local controls are disabled. If
a user interface button press is received, the unit will
display a lockout dialog for three seconds then return
to the main status display.
To disengage menu lockout:
Press and hold + and - buttons for a period of 5 seconds. The display returns to the main
status display and all controls function normally.
1
Menu's and Configuration
d
Control Symbol
If you discover a blinking "C" in the top corner of the LCD, one or more of the power
cubes has exceeded the maximum operating temperature of 90° Celsius. When
you have corrected the temperature problem, the error should clear. If the error
still persists, contact ETC Technical Services for assistance.
Press
= DMX
d
= Preset
P
= Sequence
S
= Test
T
to set the displayed language option.
CONTROLS LOCKED
ENTER UNLOCK CODE