• The scale will initially show "
parts. Press [Mode] to cycle through the options: 10, 20, 50, 100, 200
and back to 10.
• Press [Smpl] again when the number matches the number of parts
used for the sample. As more weight is added the display will show the
number of parts (
• Press [Mode] to display unit weight (
(
). The total and the unit weight are shown in the current units.
• Press [Smpl] to return to normal weighing.
4.6

ACCUMULATION

• When the scale is set for automatic accumulation, the weight will be
added to the memory when the scale becomes stable. The scale must
return to zero before another weight is added.
• When the scale is set to manual accumulation (See the Parameter
Section) the weight displayed will be stored in memory when the [Print]
key is pressed and the weight is stable.
• The display will show "
for 2 seconds before returning to displaying the weight of the item on
the scale.
• The weight will be output to a printer or PC.
• Remove the weight, allowing the scale to return to zero and put a
second weight on.
• Press [Print], the display will show "
in the memory for 2 seconds before returning to displaying the weight
of the item on the scale.
• Continue until all weights have been added.
• To view the totals in memory press the [Print] key when the scale is at
zero. The display will show "
readings) and the total weight, before returning to zero.
• The total will also be printed via the RS-232 interface.
• To clear the memory, press [Smpl] immediately after pressing [Print].
@Adam Equipment Company 2005
" asking for a sample size of 10
) with respect to the chosen sample size.
" followed by the total value in the memory
" (where " " is the total number of
7
g
), total weight (
) or the count
" followed by the new total