Installation checklist

Review the following checklist prior to turning the power on to the transmitter after installation has
been completed:
Ensure that the transmitter and sensor are properly and firmly mounted.
Ensure that stopping plugs are securely tightened on any unused conduit entries.
Ensure that the transmitter and sensor are not obstructed; transmitter and sensor are accessible
and target gas is not inhibited from reaching the sensor.
Ensure adherence to applicable local guidelines and requirements on wiring and sealing of
equipment in hazardous and non-hazardous areas.
Ensure that proper shielding and grounding practices are adhered to and local codes are being
followed.
Check system operational voltage and conditions; ensuring that they are within the applicable
specifications of the transmitter and sensor.
Verify wiring at all termination and junction points (transmitter, junction box, and power supply).
Ensure that the transmitter housing cover and sensor cap are secured tightly.