Shut Down:
1. Turn cook/filter switch OFF.
2. Turn gas control switch (2) OFF.
3. Turn gas shut-off (1) valve OFF.
AIR SHUTTER ADJUSTMENT
Maintains air/gas mixture for good combus-
tion. Start with a 1/4" gap after installing a
new gas valve or piping.
Adjustment will be necessary if main burner
flame is mostly orange or yellow. If flame is
out of adjustment, check combustion
chamber and flue for soot build-up.
If soot is present, DO NOT
operate unit and call Ser-
vice Technician. Soot is black and powdery
to the touch. See COMBUSTION CHAM-
BER.
Adjustment:
5-3
broaster.com Manual #14678 1/99 Rev 2/14
1. Loosen locknut (13) which locks air
shutter.
2. Screw shutter (14) in or out to obtain a
blue flame. Flame should start burn-
ing slightly above main burner.
3. Tighten locknut.