4 flashes
Scale not operating (not communicating).
Check the scale indicator is switched on.
Check the RS232 cable is securely attached (between the Sheep Auto
Drafter and the scale indicator).
Check the scale indicator communication settings are correct. Check you
have the correct port set up in the scale indicator for the connection
between the scales and unit (refer to the appropriate user manual).
5 flashes
Remote control not working due to PCB issue.
Replace the PCB (a rare fault). Contact your Gallagher representative for
advice on how to repair this issue.
6 flashes
Solenoid short on the 12V rail. Contact your Gallagher representative for advice
on how to repair this issue.
7 flashes
Short on the 5V loopback rail. Check for dirt or water in the indicator cable or
loopback connector, if they are clean and dry and the fault persists, contact your
Gallagher representative for advice on how to repair this issue.
10 flashes
Unit is unable to identify the cause of the fault. Contact your Gallagher
representative for advice on how to repair this issue.
Potential issues not identified by fault flash sequences:
Sheep Auto Drafter not operating
Is the green power LED on?
If no, then check there is a functional power supply connected.
Is the white mode LED flashing?
(see cause below)
Is the red E-Stop LED flashing?
(see cause below)
Is the air connected and at sufficiently high pressure?
Check the pressure gauge to see if there is enough pressure (pressure
should be in the green zone on the pressure gauge).
Are the red fault LEDs flashing?
If yes, then there is an issue that you need to resolve before the unit will
begin to work again. To find out how to activate the fault flash sequence see
the instructions above.
Page 44
3E2374 Sheep Auto Drafter User Manual