Symptom
The probe indicates
low battery condition,
but the machine control
does not.
The machine control
does not respond to the
probe being triggered or
seated.
Probe triggers but
the OMM-2C does not
respond.
No air from airblast.
Cause
Installation / CNC program fault.
Machine may not have the facility
integrated.
Probe is not switched on.
Probe is out of range.
Installation / CNC program fault.
A signal is being received
from a probe on an adjacent
machine tool.
The OMP400 or OMP600 has
the 3 second switch-on delay
selected.
The probe is out of range.
The transmission beam is
obstructed.
The probe is set to legacy
transmission.
No air to OMM-2C.
CNC program fault.
Air supply pipe damaged or
kinked.
Air blast blocked.
Action
Correct low battery SSR wiring
and/or CNC program.
Attempt to switch it on.
Change the CNC program to bring
the probe within the reception
range.
Correct M-code and/or wiring from
machine to OSI and from OSI to
OMM-2C and/or CNC program.
Change the adjacent probe to low
power mode.
Reconfigure the OMP400
or OMP600 to the standard
switch-on delay.
Review the performance
envelopes.
Check that the probe and receiver
windows are clean, and remove
any obstruction.
Reconfigure to modulated
transmission.
Check air supply to OMM-2C and
rectify.
Correct CNC program.
Check air supply pipe.
Unblock air blast.