Omm-2C Dimensions; Omm-2C Specification - Renishaw OSI Installation Manual

With multiple optical probe interface system
Hide thumbs Also See for OSI:
Table of Contents

Advertisement

OMM-2C dimensions

30°
15°
Installation
detail
Dimensions mm (in)

OMM-2C specification

Principal application
Transmission type
Probes per system
Compatible probes
Operating range
Weight (excluding
cable)
Cable (not supplied)
Mounting
Diagnostic LEDs
Pneumatic supply
Environment
22.0
(0.87)
4.8 (0.19)
M4 × 11.0 (0.43) MIN
10.0 (0.39)
Ra 1.6 (64)
Bore diameter
Ø18.02 (0.709)
Ø18.00 (0.708)
2.8 (0.11) MAX
The OMM-2C transmits control signals to the probe and receives probe
data signals for onward transmission to the OSI and CNC control.
Infrared optical transmission (modulated)
Up to three
OMP40-2, OMP40M, OLP40, OMP60, OMP60M, OMP400, OMP600 and
OTS
Up to 3 m (9.8 ft)
with airblast
80 g (2.82 oz)
without airblast
80 g (2.82 oz)
Specification
Ø4.75 mm (0.19 in), 12 core screened cable
each core 7 × 0.1 mm
Length
8 m (26.2 ft), 15 m (49.2 ft)
Specifically designed for mounting in the machine spindle.
Start, error, active system and signal condition.
Ø3 mm (0.12 in) pneumatic fitting, 9 bar (130.5 psi) max. The air supply to
the OMM-2C must conform to ISO 8573-1: Class 1.7.2.
IP rating
IPX6 (EN/IEC 60529) [for product]
IPX8 (EN/IEC 60529) [for glass window]
IK rating
IK04 (EN/IEC 62262) [for glass window]
Storage temperature
−25 °C to +70 °C (−13 °F to +158 °F)
Operating temperature +5 °C to +55 °C (+41 °F to +131 °F)
66.0 (2.60)
Binder connector
30.0 (1.18)
(series 702)
09-0427-90-08
× 6.0 (0.24) MIN DEPTH
2.15