Universal auto changeover up to 2 heat / 2 cool conventional and heat pump thermostat
Hide thumbs Also See for Premier Series:

Advertisement

4
Programming Installer Settings
Installer Options
Factory Default Options
aes
1 – Residential or
Commercial
pao
7
2 – Programming
6
Mode
12h
3 – 12/24 Clock
de
F
4 – Temperature Scale
6
autoON
5 – Auto Changeover
band 3
6 – Dead Band
C
7 – System Type
11
H6
8 – First Stage
1
Fan Control
HE
9 – Second Stage
2
Fan Control
auh AE
10 – Fossil Fuel
Backup Option
off-AC
11 – AC Power
Interrupt Warning
cpopOFf
12 – Compressor
Power Outage
Protection
cscp 5
13 – Short Cycle
Protection
fan60
14 – Residual Cooling
Fan Off Delay
ciacOFf
15 – Recirculating Fan
Lock
aec ON
16 – Enable / Disable
ARM
se
s1
17 – Set Sensor
n
Control
sec 2
18 – Set Security Level
for Keypad Lock
cont.
Comment
aes, bus
Selects a Residential or
Commercial (BUS) profile.
pao
7,
6
Not available if thermostat
pao
52,
6
is in the Commercial
pao
NO
(BUS) profile.
6
12h, 24h
Selects either 12 hour or
24 hour clock.
de
F, de
C
Selects either Fahrenheit
6
6
or Celsius.
autoON,
Either enables or disables
autoOFf
Auto Changeover.
band 2, band 3,
Selects Auto Changeover
band 4,
Dead Band of 2, 3, 4 or 5º F
band 5
(1.5, 2.0, 3.0º C), if Auto
Changeover is enabled.
C,
C,
11
22
Selects single stage
HP,
HP
11
22
conventional, 2 stage conventional,
single stage heat pump, or 2 stage
heat pump.
HG,
HE
1
1
Not available with a heat pump
system. Selects between 1st
stage gas or electric heat.
HE,
H6
Only available with a 2nd stage
2
2
heat pump system. Selects
between 2nd stage gas or
electric heat.
auh AE,
Only available with a 2nd stage
auh A6
heat pump system. Locks out 1st
stage during 2nd stage heat call
for fossil fuel backup systems
(AUXAG). With an electric backup
system (AUXAE) both stages
will run.
off-AC,
Only available when thermostat is
on-AC
installed as a hardwired unit.
Select between turning the AC
power interrupt warning off or on.
cpopOFf,
Only available with 2nd stage heat
cpopON
pump and AC power connected.
Select between compressor lock
off and compressor lock on.
cscp 5, cscp 4,
Selects 5, 4, 3, 2 or 0
cscp 3, cscp 2,
minutes for the compressor
cscp 0
short cycle protection.
fan00,
Selects 0, 30, 60 or 90 seconds as
fan30,
the time the fan will stay on after
fan60,
the cooling system has satisfied
fan90
the set point temperature and has
turned off the compressor.
ciacOFf,
Selects between Recirculating
ciacON
Fan Lock off or on.
aec ON,
Enables or disables ARM
aec OFf,
Not available in non-
programmable mode.
se
s1,
n
Selects between Internal,
se
sE,
n
External and Averaging sensor
se
sA
n
control. This is only available if
the remote sensor is connected.
sec 1,
Selects between level 1 or level
sec 2
2 keypad lockout.
6
4
Programming Installer Settings
1. Selects Residential or Commercial (BUS) profile. Determines programming
events per day. If Residential is selected, 4 events per day are available. If
Commercial is selected, 2 events per day are available. Only the 7 day
programmable mode is available for the Commercial profile.
2. Selects the programming mode, either full 7 day or 5-2 day (weekday-
weekend) programming or non-programmable. If the Commercial profile was
selected in step 1 this option is not available.
3. Selects either a 12 hour or 24 hour clock.
4. Selects preferred temperature scale of either ºF or ºC.
5. Selects either Auto Changeover on or off. When off is selected, the AUTO icon
will not be displayed when selecting the system options with the system switch.
When Auto Changeover mode is enabled and selected, the system automatically
switches between heating and cooling when the room temperature meets the
programmed heating or cooling set points.
6. When Auto Changeover mode is enabled and selected, the system automati-
cally switches between heating and cooling when the room temperature
meets the normal criteria for either a heating or cooling call. There is a forced
separation (dead band) between the heating and cooling set points, so the
systems do not work against each other. This option selects Auto Changeover
Dead Band of 3, 4 or 5º F (1.5, 2.0, 3.0º C) the default is 3º F.
7. Selects single stage conventional (11C), 2 stage conventional (22C), single
stage heat pump (11HP), or 2 stage heat pump (22HP). Any change made to
the system type resets Installer Options 8 through 12 to their default values
dependent on system selected.
8. Selects between 1st stage gas or electric heat. This Installer Option is not
available with a heat pump system.
9. Selects between 2nd stage gas or electric heat. This Installer Option is only
available with a 2 stage heat pump system.
10. For heat pump units with an electric auxiliary stage, both the first and second
stages of heating will run when a call for second stage heat is made. For heat
pump units with a fossil fuel auxiliary stage, the first stage will be locked out
one minute after a second stage heat call, and the second stage will only
be used.
11. Select between turning the AC power interrupt warning off or on. During a
power loss, the thermostat will display an outage warning. The system clock
will continue to run, and all settings will be maintained until the outage period
is over. This Installer Option is only available when thermostat is installed as a
hardwired unit.
12. This thermostat provides cold weather compressor protection by locking out
the compressor stage (1st stage) of heating for a period of time after a power
outage greater than 60 minutes. The lockout period is one hour less than the
outage time, up to a maximum of 12 hours. During that period of time, the
auxiliary heat stage will still be available to maintain the set point temperature.
The compressor lockout can be disabled by setting this option to OFF.
.
13. This thermostat includes an automatic compressor protection feature to avoid
potential damage to the cooling system from short cycling. This thermostat
automatically provides an adjustable delay after turning off the cooling system
output to protect the compressor. This protection is also present in the heat
mode of operation on single stage heat pump systems to protect the compressor.