Protection and Malfunction Parameter Group
NO.
Function description
Bus over voltage
F10.06
suppression function
Bus over voltage
F10.07
suppression point
Bus over voltage
F10.08
suppression gain
Short-circuit detection
F10.14
after power on
phase missing
F10.15
protection
Motor overload
F10.16
protection curve
coefficient
Malfunction
F10.38
self-recovery times
Malfunction
F10.39
self-recovery interval
time
Communication Control Function Parameter Group
NO.
Function description
Range of settings and definition
LED"0" digit: Over voltage
suppression
0: Invalid
1: Valid in DEC
2: Valid both in ACC/DEC
LED"00" digit: Over-excitation
control
0: off
1: on
LED"000"/"0000": Reserved
110.0~150.0%
0.0~500.0%
LED "0" digit: Earth short-circuit
detection after power on
0: off
1: on
LED"00" digit: Fan short-circuit
detection after power
0: off
1: on
LED"0" digit: Output phase missing
protection
0: off
1:on
LED"00" digit: Input phase missing
protection
0: off
1: Open Alarm
2: Open Fault(STOP VFD)
LED"000" /"0000" digit: Reserved
0.0~250.0%
0~5
0.1~100.0s
Range of setting and definition
23
SI23 Solar Pump Inverter Manual
Factory
Feature
default
〇
0012
※
128.0%
●
100.0%
〇
11
〇
0021
〇
100.0%
〇
0
〇
1.0s
Factory
Feature
default
Address
0xA06
0xA07
0xA08
0xA0E
0xA0F
0xA10
0xA26
0xA27
Address