G/P Model
F00.17
Setting
F00.18
Reserved
Parameter
F00.19
initialization
Operation Control Parameters Group
NO.
Function description
F01.10
Stop mode
F01.16
ACC/DEC selection
Power off restart action
F01.35
selection
Power off restart
F01.36
waiting time
Switching value terminal parameters
NO.
Function description
F02.00
Input terminal 1(X1)
F02.01
Input terminal 2(X2)
F02.02
Input terminal 3(X3)
F02.03
Input terminal 4(X4)
Terminal operate
F02.24
protection
0: Invalid
1: Valid
LED"0000"digit: reserved
0:G Type
1:P Type
0: No action
1: Restore factory default (not restoring motor parameters)
2: Restore factory default (restoring motor parameters)
3: Clear malfunction records
Range of settings and definition
0:DEC stop
LED "0" digit: time base selection
0: max frequency
1: fixed frequency 50Hz
2: set frequency
LED"00"digit: S ACC/DEC selection
0: Beeline ACC/DEC
1: S Curve ACC/DEC
LED "000" digit: reserved
LED "0000" digit: reserved
0:Invalid
0.00~60.00s
Range of setting and definition
0: No function
1:Forward
2:Reverse
80: Water fulfilled detect alarm
81:Water fulfilled detect reset
0: OFF
1:ON
LED "0" digit: Terminal operate protection
when abnormal exit
LED "00" digit: Jog terminal operate
SI23 Solar Pump Inverter Manual
1:Free stop
1:Valid
16
●
0
0x011
〇
0
0x013
●
0
0x10A
〇
0000
0x110
〇
0
0x123
〇
0.50s
0x124
〇
1
0x200
〇
2
0x201
〇
80
0x202
〇
81
0x203
〇
0111
0x218