Rated Indoor Airflow (Cfm) - Bryant 551J*07A/G Series Installation Instructions Manual

Single package rooftop cooling only sizes 07, 08, 09, 11 and 12 with puronr (r--410a) refrigerant
Table of Contents

Advertisement

Rated Indoor Airflow (cfm)

The table to the right lists the rated indoor airflow used
for the AHRI efficiency rating for the units covered in this
document.
Model
551J = Cooling RTU with optional
High Efficient Electric Heat
Voltage
E = 460-3-60
P = 208/230-3-60
T = 575-3-60
Cooling Tons
07 - 6 ton
08 - 7.5 ton
09 - 8.5 ton
11 - 10 ton (12.0 EER)
12 - 10 ton (11.7 EER)
Refrigerant System/Gas Heat Options
A = Standard One-Stage Cooling Models
D = Two Stage Cooling Models
G = Standard One Stage Cooling Models and Perfect Humidity
K = Two Stage Cooling Models and Perfect Humidity
Heat Level
(Field-installed electric heaters available)
000 = No Heat
Coil Options (Outdoor – Indoor – Hail Guard)
A = Al/Cu – Al/Cu
B = Precoat Al/Cu – Al/Cu
C = E-coat Al/Cu – Al/Cu
D = E-coat Al/Cu – E-Coat Al/Cu
E = Cu/Cu – Al/Cu
F = Cu/Cu – Cu/Cu
M = Al/Cu – Al/Cu – Louvered Hail Guards
N = Precoat Al/Cu – Al/Cu – Louvered Hail Guards
P = E-coat Al/Cu – Al/Cu – Louvered Hail Guards
Q = E-coat Al/Cu – E-coat Al/Cu – Louvered Hail Guards
R = Cu/Cu – Al/Cu – Louvered Hail Guards
S = Cu/Cu – Cu/Cu – Louvered Hail Guards
1
2
3
4
5
6
7
8
5
5
1
J
E
1
2
D
TM
Fig. 1 - - 551J*07- - 12 Model Number Nomenclature (Example)
Model Number
551J*07A/G
551J*07D/K
551J*08D/K
551J*09D/K
551J*11D/K
551J*12D/K
9
10 11 12 13 14 15 16 17
0
0
0
A
3
A
0
A
Factory-Installed Options
0A = None
Outdoor Air Options
A = None
B = Temperature Economizer w/ Barometric Relief
and W7212 Economizer Controller
E = Temperature Economizer w/ Barometric Relief, CO
and W7212 Economizer Controller
H = Enthalpy Economizer w/ Barometric Relief
and W7212 Economizer Controller
L = Enthalpy Economizer w/ Barometric Relief, CO
and W7212 Economizer Controller
Q = Motorized 2 Position Damper w/ Barometric Relief
U = Temperature Ultra Low Leak Economizer
w/ Barometric Relief
W = Enthalpy Ultra Low Leak Economizer w/ Barometric Relief
Indoor Fan Options
1 = Standard Static Option – Belt Drive
2 = Medium Static Option – Belt Drive
3 = High Static Option – Belt Drive
3
Full Load Airflow (cfm)
2400
2400
3000
3000
3000
3000
A
Packaging and 2-Speed Indoor Fan Motor
A = Standard Packaging, electro-mechanical
controls that require W7212 EconoMi$er
B = LTL Packaging, electro-mechanical controls
that require W7212 EconoMi$er IV
C = Standard Packaging, electro-mechanical
controls that require W7220 EconoMi$er X
D = Standard Packaging and 2-speed Indoor Fan
Motor (VFD) Controller
E = LTL Packaging and 2-speed Indoor Fan
Motor (VFD) Controller
F = LTL Packaging, electro-mechanical controls
that require W7220 EconoMi$er X
NOTE: See the 551J 3 to 15 ton Price Pages for a
complete list of factory-installed options.
®
IV
2
2
a551J--- 008

Advertisement

Table of Contents
loading

Table of Contents